Program 82 : Basic Hardware Setup for Extension
Level:
IN
Description
Use Program 82-11 : SLI Initial Setup to define the various timers for SLI Packages.
Input Data
Item
Item
No.
01
Bounce Protect Time
HookFlash Start Time
02
03
HookFlash End Time
Feature Cross Reference
None
2 - 506
Description
Specify a time for detection of a
valid 0ff-Hook indication that is
long enough to prevent an
unintentional bounce of the
receiver from being detected as
a new Off-Hook indication from a
Single Line Telephone.
Specify the minimum hookflash
time from a Single Line
Telephone or analog Voice Mail
system before it is detected as
the beginning of a valid
hookflash.
Specify the maximum hookflash
duration from a Single Line
Telephone to receive a second
dial tone.
Conditions
None

82-11 : SLI Initial Setup

Input
0 = No Setting
1~15 = 100ms~1.5sec
0 = 40ms
1~15 = 90ms~790ms
0 = HST+0ms
1~15 =
HST+100ms~HST+1500ms
(HST=Hookflash Start Time)