Position control by manual pulse generator operation
In manual pulse generator operation, the position is moved by a "manual pulse generator 1 pulse movement amount" per
pulse. The feed current value in the positioning control by manual pulse generator operation can be calculated using the
expression shown below.
Feed current value = Number of input pulses  [Cd.20] Manual pulse generator 1 pulse input magnification  Manual pulse
generator 1 pulse movement amount
[Pr.1] Unit setting
Manual pulse generator 1 pulse movement amount
For example, when "[Pr.1] Unit setting" is mm and "[Cd.20] Manual pulse generator 1 pulse input magnification" is 2, and 100
pulses are input from the manual pulse generator, the feed current value is as follows.
100  2  0.1 = 20 [m] ("[Md.20] Feed current value" = 200)
The number of pulses output actually to the servo amplifier is "Manual pulse generator 1pulse movement amount/movement
amount per pulse".
The movement amount per pulse can be calculated using the expression shown below.
Movement amount per pulse =
For example, when "[Pr.1] Unit setting" is mm and the movement amount per pulse is 1 m, 0.1/1 = 1/10, i.e., the output to the
servo amplifier per pulse from the manual pulse generator is 1/10 pulse. Thus, the Motion module outputs 1 pulse to the servo
amplifier after receiving 10 pulses from the manual pulse generator.
Speed control by manual pulse generation operation
The speed during positioning control by manual pulse generator operation is a speed corresponding to the number of input
pulses per unit time, and can be obtained using the following equation.
Output command frequency = Input frequency  [Cd.20] Manual pulse generator 1 pulse input magnification
5 MANUAL CONTROL
180
5.4 Manual Pulse Generator Operation
Downloaded from
ManualsNet.com
mm
0.1 m
[Pr.3] Movement amount per rotation (AL)
[Pr.2] Number of pulses per rotation (AP)
search engine
inch
degree
0.00001 inch
0.00001 degree
× [Pr.4] Unit magnification (AM)
pulse