■[Da.11] Shape, [Da.12] Start data No.
Use the following calculation formula.
• 22000 + (400  (Ax - 1)) + (200  M) + (P - 1)
For each variable, substitute a number following the description below.
Variable
Ax
M
P
Ex.
When the buffer memory address that satisfies the following conditions is determined
• Axis 3
• Start block No.2
• Block start data point: 40
22000 + (400  (3 - 1)) + (200  2) + (40 - 1) = 23239
■[Da.13] Special start instruction, [Da.14] Parameter
Use the following calculation formula.
• 22050 + (400  (Ax - 1)) + (200  M) + (P - 1)
For each variable, substitute a number following the description below.
Variable
Ax
M
P
Ex.
When the buffer memory address that satisfies the following conditions is determined
• Axis 2
• Start block No.1
• Block start data point: 25
22050 + (400  (2 - 1)) + (200  1) + (25 - 1) = 22674
APPX
656
Appendix 2 How to Determine Buffer Memory Addresses
Downloaded from
ManualsNet.com
Description
The axis No. of the buffer memory address to be determined. Substitute a number from 1 to 32.
The start block No. of the buffer memory address to be determined. Substitute a number from 0 to 4.
The block start data point of the buffer memory address to be determined. Substitute a number from 1 to 50.
Description
The axis No. of the buffer memory address to be determined. Substitute a number from 1 to 32.
The start block No. of the buffer memory address to be determined. Substitute a number from 0 to 4.
The block start data point of the buffer memory address to be determined. Substitute a number from 1 to 50.