Memory Configuration And Data Process; Configuration And Roles - Mitsubishi Electric MELSEC iQ-R Series User Manual

Programmable
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

12.9
The memory configuration and data transmission of the Motion module are explained in this section.
The Motion module is equipped with four memories. By understanding the configuration and roles of the four memories, the
internal data transmission process of the Motion module, such as "when the power is turned ON" or "when the PLC READY
signal [Y0] changes from OFF to ON", can be easily understood. This also allows the transmission process to be carried out
correctly when saving or changing the data.

Configuration and roles

The Motion module is equipped with the following four memories.
: Setting and storage area provided, Not possible: Data is lost when power is turned OFF.
: Setting and storage area not provided, Possible: Data is held even when power is turned OFF.
Memory
configuration
Buffer memory
Internal memory
Flash ROM
Internal memory
(nonvolatile)
Memory
configuration
Buffer memory
Internal memory
Flash ROM
Internal memory
(nonvolatile)
*1 Parameter only
*2 The areas are included in the Simple Motion module setting.
Downloaded from
ManualsNet.com

Memory Configuration and Data Process

Role
Area that can be directly accessed
with a program with a CPU module
Area that can be set only with the
engineering tool
Area that can be set only using
buffer memory
Area for backing up data required
for positioning
Area for backing up servo
parameter or cam data
Role
Area that can be directly accessed
with a program with a CPU
module
Area that can be set only with the
engineering tool
Area that can be set only using
buffer memory
Area for backing up data required
for positioning
Area for backing up servo
parameter or cam data
search engine
Area configuration
Parameter
Monitor
Control
*2
area
data area
data area
Area configuration
Servo
Synchronous
Cam
parameter
control
area
*2
*2
area
area
*1
Positioning data
*2
area
(No.1 to
(No.101
100)
to 600)
Backup
*2
Not possible
Not possible
Not possible
Possible
Possible
12 DATA USED FOR POSITIONING CONTROL
12.9 Memory Configuration and Data Process
12
Block start data
*2
area
(No.7000
(No.7002
to 7001)
to 7004)
549