Axis control data

[Cd.3] Positioning start No.
Sets the positioning start No. (Only 1 to 600 for the Pre-reading start function. For details, refer to Page 270 Pre-reading
start function.)
Fetch cycle: At start
■Setting value
• Set with a decimal.
Setting value
1 to 600
7000 to 7004
9001
9002
9003
9004
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".
[Cd.4] Positioning starting point No.
• Sets a "starting point No." (1 to 50) if block start data is used for positioning. (Handled as "1" if the value other than 1 to 50
is set.)
• The Motion module resets the value to "0" automatically when the continuous operation is interrupted.
Fetch cycle: At start
■Setting range
• Set with a decimal.
Setting range of [Cd.4]
1 to 50
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".