Section 12
Monitoring
Name
InfNo37
FunType38
InfNo38
FunType39
InfNo39
FunType40
InfNo40
Table 211: A4RADR Non group settings (advanced)
Name
NomValue31
UnderTrigOp31
UnderTrigLe31
OverTrigOp31
OverTrigLe31
NomValue32
UnderTrigOp32
UnderTrigLe32
OverTrigOp32
OverTrigLe32
NomValue33
UnderTrigOp33
UnderTrigLe33
OverTrigOp33
OverTrigLe33
NomValue34
UnderTrigOp34
UnderTrigLe34
OverTrigOp34
Table continues on next page
194
Values (Range)
Unit
0 - 255
-
0 - 255
-
0 - 255
-
0 - 255
-
0 - 255
-
0 - 255
-
0 - 255
-
Values (Range)
Unit
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
© 2021 Hitachi Energy. All rights reserved.
Step
Default
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Step
Default
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1MRK 511 557-UEN Rev. A
Description
Information number for analog channel
37 (IEC-60870-5-103)
Function type for analog channel 38
(IEC-60870-5-103)
Information number for analog channel
38 (IEC-60870-5-103)
Function type for analog channel 39
(IEC-60870-5-103)
Information number for analog channel
39 (IEC-60870-5-103)
Function type for analog channel 40
(IEC-60870-5-103)
Information number for analog
channel40 (IEC-60870-5-103)
Description
Nominal value for analog channel 31
Use under level trigger for analog
channel 31 (on) or not (off)
Under trigger level for analog channel 31
in % of signal
Use over level trigger for analog channel
31 (on) or not (off)
Over trigger level for analog channel 31
in % of signal
Nominal value for analog channel 32
Use under level trigger for analog
channel 32 (on) or not (off)
Under trigger level for analog channel 32
in % of signal
Use over level trigger for analog channel
32 (on) or not (off)
Over trigger level for analog channel 32
in % of signal
Nominal value for analog channel 33
Use under level trigger for analog
channel 33 (on) or not (off)
Under trigger level for analog channel 33
in % of signal
Use over level trigger for analog channel
33 (on) or not (off)
Overtrigger level for analog channel 33
in % of signal
Nominal value for analog channel 34
Use under level trigger for analog
channel 34 (on) or not (off)
Under trigger level for analog channel 34
in % of signal
Use over level trigger for analog channel
34 (on) or not (off)
Technical Manual