Table 393: SRCSELECT Input signals
Name
INPUT1-1
INPUT1-2
INPUT1-3
INPUT1-N
INPUT2-1
INPUT2-2
INPUT2-3
INPUT2-N
INPUT3-1
INPUT3-2
INPUT3-3
INPUT3-N
INPUT4-1
INPUT4-2
INPUT4-3
INPUT4-N
INPUT5-1
INPUT5-2
INPUT5-3
INPUT5-N
DIAG5DATA
DIAG5SYNCH
DIAG5SMPLT
DIAG5SYNMU
DIAG5TSTMD
INPUT6-1
INPUT6-2
INPUT6-3
Table continues on next page
412
Type
Default
Description
STRING
0
First analog input used for phase L1 or L1-L2 quantity of INPUT1
STRING
0
Second analog input used for phase L2 or L2-L3 quantity of
INPUT1
STRING
0
Third analog input used for phase L3 or L3-L1 quantity of INPUT1
STRING
0
Fourth analog input used for residual or neutral quantity of
INPUT1
STRING
0
First analog input used for phase L1 or L1-L2 quantity of INPUT2
STRING
0
Second analog input used for phase L2 or L2-L3 quantity of
INPUT2
STRING
0
Third analog input used for phase L3 or L3-L1 quantity of INPUT2
STRING
0
Fourth analog input used for residual or neutral quantity of
INPUT2
STRING
0
First analog input used for phase L1 or L1-L2 quantity of INPUT3
STRING
0
Second analog input used for phase L2 or L2-L3 quantity of
INPUT3
STRING
0
Third analog input used for phase L3 or L3-L1 quantity of INPUT3
STRING
0
Fourth analog input used for residual or neutral quantity of
INPUT3
STRING
0
First analog input used for phase L1 or L1-L2 quantity of INPUT4
STRING
0
Second analog input used for phase L2 or L2-L3 quantity of
INPUT4
STRING
0
Third analog input used for phase L3 or L3-L1 quantity of INPUT4
STRING
0
Fourth analog input used for residual or neutral quantity of
INPUT4
STRING
0
First analog input used for phase L1 or L1-L2(not in case of MU)
quantity of INPUT5
STRING
0
Second analog input used for phase L2 or L2-L3(not in case of
MU) quantity of INPUT5
STRING
0
Third analog input used for phase L3 or L3-L1(not in case of MU)
quantity of INPUT5
STRING
0
Fourth analog input used for residual or neutral quantity of
INPUT5
BOOLEAN
0
Serious data loss from MU over INPUT5 group
BOOLEAN
0
MU clock not synced to same clock as IED over INPUT5 group
BOOLEAN
0
Sample lost; Current sample estimated for MU over INPUT5
group
BOOLEAN
0
SmpSynch flag in frame for MU not ok over INPUT5 group
BOOLEAN
0
Used channel from MU is in testmode over INPUT5 group
STRING
0
First analog input used for phase L1 or L1-L2(not in case of MU)
quantity of INPUT6
STRING
0
Second analog input used for phase L2 or L2-L3(not in case of
MU) quantity of INPUT6
STRING
0
Third analog input used for phase L3 or L3-L1(not in case of MU)
quantity of INPUT6