Settings - Hitachi Relion 650 Series Technical Manual

Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

1MRK 511 557-UEN Rev. A
Name
LOPRIL1AL
LOPRIL2AL
LOPRIL3AL
12.22.5

Settings

Table 296: CBLEARN Non group settings (basic)
Name
Values (Range)
DefaultNOOpTimeL1
DefaultNOOpTimeL2
DefaultNOOpTimeL3
DefaultNCOpTimeL1
DefaultNCOpTimeL2
DefaultNCOpTimeL3
DefaultPriOpTimeL1
DefaultPriOpTimeL2
DefaultPriOpTimeL3
DefaultNOClTimeL1
DefaultNOClTimeL2
DefaultNOClTimeL3
DefaultNCClTimeL1
DefaultNCClTimeL2
DefaultNCClTimeL3
DefaultPriClTimeL1
DefaultPriClTimeL2
DefaultPriClTimeL3
TimeOutAlarmDelay
Table continues on next page
Technical Manual
Type
BOOLEAN
BOOLEAN
BOOLEAN
Unit
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 200.0
ms
1.0 - 1500.0
ms
© 2021 Hitachi Energy. All rights reserved.
Description
Alarm if Primary contact operating time last operation for phaseL1
is not in the tolerance limit
Alarm if Primary contact operating time last operation for phaseL2
is not in the tolerance limit
Alarm if Primary contact operating time last operation for phaseL3
is not in the tolerance limit
Step
Default
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
0.1
10.0
1.0
500.0
Description
Default operating time of NO contact for
open command for phaseL1
Default operating time of NO contact for
open command for phaseL2
Default operating time of NO contact for
open command for phaseL3
Default operating time of NC contact for
open operation for phase L1
Default operating time of NC contact for
open operation for phase L2
Default operating time of NC contact for
open operation for phase L3
Default operating time of primary contact
for open operation for phase L1
Default operating time of primary contact
for open operation for phase L2
Default operating time of primary contact
for open operation for phase L3
Default operating time of NO contact for
Close operation for phaseL1
Default operating time of NO contact for
Close operation for phaseL2
Default operating time of NO contact for
Close operation for phaseL3
Default operating time of NC contact for
Close operation for phaseL1
Default operating time of NC contact for
Close operation for phaseL2
Default operating time of NC contact for
Close operation for phaseL3
Default operating time of primary contact
for close operation for phase L1
Default operating time of primary contact
for open operation for phase L2
Default operating time of primary contact
for open operation for phase L3
Maximum time delay for status change
of auxiliary & primary contacts after
receiving input command
Section 12
Monitoring
PID-6446-SETTINGS v1