NEC Express5800 140Rd-4 User Manual page 112

Windows server 2003 x64 editions
Hide thumbs Also See for Express5800 140Rd-4:
Table of Contents

Advertisement

4-30
Menu
• No of Cycles
+Reset Battery Charge Counter
+Other Adapter Options
*8
Emulation
*9
Auto Rebuild
• Initiator ID
*10
Cluster Mode
*11
Multiple PCI Delayed Trans
*12
Force Boot
*13
Coercion Algorithm
Abort BI & CC Activities
*14
CC Restoration
*15
Temporary Offline RAID
+Logical Drive
+Logical Drives
+Initialize
+Check Consistency
+View/Update Parameters
• RAID
• SIZE
• Stripe SIZE
+√ Write Policy
+√ Read Policy
+√ Cache Policy
+√ FlexRAID Virtual Sizing
• #Stripes
• State
+Physical Drive
+Physical Drive Selection Menu
+Rebuild
+Format
+Make Online
+Fail Drive
+Make HotSpare
+View Drive Information
• Device Type
• Capacity
• Vender ID
• Product ID
• Revision
• SCSI Standard
• Media Errors
• Other Errors
*16
Synchronous Negotiation
*17
SCSI Command Q Tagging
+Channel
+Channels
*18
Termination State
*19
Enable Auto Termination
*20
SCSI Transfer rate
+Format
+Rebuild
+Check Consistency
+Select Adapter
Description
The number charge cycle
Clear battery charge counter
Adapter detailed options
Set control mode
Set auto rebuilding Enable / Disable
Indicate Initiator ID No.
Set cluster mode
Set PCI bus bridge
Forced setting of configuration information(HDD)
Setting parameter for maximum hard disk capacity
Abort Background initialize or Check Consistency
Select CC Restoration mode
Set Temporary offline Enable / Disable
Logical drive operation
Select logical drive
Initialize logical drive
Check logical drive redundancy
Display logical drive information
Display RAID level
Display logical drive capacity
Display stripe size
Set write mode
Set read mode
Set cache mode
Set virtual sizing Enable / Disable *Do not set to Enable
Display stripe size
Display logical drive status
Physical drive menu
Physical drive operation
Perform rebuilding
Perform low level format
Set the disk online
Set the disk offline
Set as stand-by disk for auto rebuilding
Display hard disk information
Hard disk type
Hard disk capacity
Hard disk vender name
Hard disk model
Hard disk revision
SCSI standard
The number of media errors
The number of other errors
SCSI synchronous negotiation
Set SCSI command Q Tag
Set channel
Chose SCSI channel
Set termination state
Set auto termination state
Set transfer rate
Perform low level format
Perform rebuilding
Perform logical drive redundancy check
Select disk array controller
* This menu item does not appear if no disk array controller is installed in the
computer.
*Do not use
*Do not use

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents