8-18
Error
Error message
code
8140
DIMM group #1 with error is enabled.
8141
DIMM group #2 with error is enabled.
8142
DIMM group #3 with error is enabled.
8143
DIMM group #4 with error is enabled.
8144
DIMM group #5 with error is enabled.
8145
DIMM group #6 with error is enabled.
8146
DIMM group #7 with error is enabled.
8147
DIMM group #8 with error is enabled.
8150
NVRAM Cleared By Jumper.
8151
Password Cleared By Jumper.
8160
Mismatch Processor Speed detected on Processor 1.
8161
Mismatch Processor Speed detected on Processor 2.
8162
Mismatch Processor Speed detected on Processor 3.
8163
Mismatch Processor Speed detected on Processor 4.
8170
Processor 1 not operating at intended frequency
8171
Processor 2 not operating at intended frequency
8172
Processor 3 not operating at intended frequency
8173
Processor 4 not operating at intended frequency
817F
All processors not operating at intended frequency
8200
Online Spare Memory was not ready.
8201
Mirroring Memory was not ready.
8202
Memory RAID was not ready.
8300
Secondary BIOS is corrupted.
Other POST Errors
The following message does not appear on the screen, however, it is recorded in the system event log.
Error code
Description
8301
A BIOS Checksum error was detected in the
early stage of BIOS boot-up (Bootblock). The
control was transferred to the secondary BIOS.
(See Chapter 2 "Recovering BIOS Data".)
Recommended Action
Contact your service representative to replace the two
DIMMs in the relevant group.
Turn off the power. Then recover the jumper setting to the
original setting.
Check the frequency of the processor. If it is unknown,
contact your service representative.
DIMM type mismatch is detected when the online spare
memory feature is enabled.
Contact your service representative.
DIMM type mismatch is detected or unnecessary
installation in group #2 is detected when the memory
mirroring feature is enabled. Check the DIMM type or
installation. If the error cannot be corrected, contact your
service representative.
Check if capacity, type, and installation status of all DIMMs
are correct.
Contact your service representative.
Recommended Action
Contact your service
representative.

Advertisement