NEC Express5800 140Rd-4 User Manual page 218

Windows server 2003 x64 editions
Hide thumbs Also See for Express5800 140Rd-4:
Table of Contents

Advertisement

8-16
Error
Error message
code
0611
IDE configuration changed.
0613
COM A configuration changed.
0614
COM A config. error - device disabled.
0615
COM B configuration changed.
0616
COM B config. error - device disabled.
0617
Floppy configuration changed.
0618
Floppy config. error - device disabled.
0619
Parallel port configuration changed.
061A
Parallel port config. error - device disabled.
0B00
Rebooted during BIOS boot at Post Code.
0B1B
PCI System Error on Bus/Device/Function.
0B1C
PCI Parity Error on Bus/Device/Function.
0B28
Unsupported Processor detected on Processor 1.
0B29
Unsupported Processor detected on Processor 2.
0B2A
Unsupported Processor detected on Processor 3.
0B2B
Unsupported Processor detected on Processor 4.
0B30
Fan 1 Alarm occurred.
0B31
Fan 2 Alarm occurred.
0B32
Fan 3 Alarm occurred.
0B33
Fan 4 Alarm occurred.
0B34
Fan 5 Alarm occurred.
0B35
Fan 6 Alarm occurred.
0B50
Processor #1 with error taken off line.
0B51
Processor #2 with error taken offline.
0B52
Processor #3 with error taken offline.
0B53
Processor #4 with error taken offline.
0B5F
Forced to use Processor with error
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
0B66
DIMM group #7 has been disabled
0B67
DIMM group #8 has been disabled
0B70
The error occurred during temperature sensor reading.
0B71
System Temperature out of the range.
0B74
The error occurred during voltage sensor reading.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
0B7C
The error occurred during redundant power module
confirmation
0B7D
The normal operation can't be guaranteed with use of only
one PSU
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
Recommended Action
Contact your service representative.
Make sure that the server supports the processor. If you
are not sure, contact your service representative to
request the maintenance.
A fan failure or fan clogging may occur. Contact your
service representative to request the maintenance.
The processor is degraded. Contact your service
representative.
Because an error is detected in every processor, the
system is forcibly started. Contact your service
representative.
Contact your service representative.
A fan failure or fan clogging may occur. Contact your
service representative to request the maintenance.
Contact your service representative.
Contact you service representative to replace the power
supply unit.
Contact you service representative to add an additional
power supply unit or replace the existing power supply
unit.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.