Mitsubishi Electric GT1685 Connection Manual page 100

Got1000 series
Table of Contents

Advertisement

2.1 MELSEC iQ-R, RnMT
The table below shows the device ranges in [MELSEC iQ-
R, RnMT] as the controller type.
Device name
Input (X)
Output (Y)
*1
Internal relay (M)
Latch relay (L)
*5
Step relay (S)
Annunciator (F)
*1
Link relay (B)
Contact (TT)
*1
Timer
Coil (TC)
Contact (LTT) LTT0 to LTT2529407
Long timer
Coil (LTC)
*1*2
Contact (CT)
*1
Counter
Coil (CC)
Contact
Long
(LCT)
*1
counter
Coil (LCC)
Special relay (SM)
Retentive
Contact (SS)
*1
timer
Coil (SC)
Long
Contact
retentive
(LSS)
*1*2
timer
Coil (LSC)
SFC block (BL)
Step relay (block)(BLS)
*1
Link special relay (SB)
Remote input (RX)
Remote output (RY)
Link relay (LB)
Bit-specified word device
(Except the timer, counter,
retentive timer, and index
register (Z))
*1
Data register (D)
Special data register (SD)
*1
Link register (W)
Timer
*1
(current value) (TN)
Counter
*1
(current value) (CN)
Retentive timer
*1
(current value) (SN)
*1
Link special register (SW)
2 - 8
2. DEVICE RANGE THAT CAN BE SET
2.1 MELSEC iQ-R, RnMT
Device No.
Setting range
representation
X0 to X3FFF
Hexadecimal
number
Y0 to Y3FFF
M0 to M161882111
L0 to L32767
Decimal
number
S0 to S16383
F0 to F131071
Hexadecimal
B0 to B9A61FFF
number
TT0 to TT8993439
TC0 to TC8993439
LTC0 to LTC2529407
CT0 to CT8993439
CC0 to CC8993439
LCT0 to LCT4761215
Decimal
LCC0 to LCC4761215
number
SM0 to SM4095
SS0 to SS8993439
SC0 to SC8993439
LSS0 to LSS2529407
LSC0 to LSC2529407
BL0 to BL319
BLS0 to BLS511
SB0 to SB9A61FFF
RX0 to RX3FFF
Hexadecimal
number
RY0 to RY3FFF
LB0 to LB7FFF
Setting range of each
-
word device
D0 to D10117631
Decimal
number
SD0 to SD4095
Hexadecimal
W0 to W9A61FF
number
TN0 to TN8993439
Decimal
CN0 to CN8993439
number
SN0 to SN8993439
Hexadecimal
SW0 to SW9A61FF
number
Device name
File register (R)
R0 to R32767
Extension
Block
0 to 255
file register
Device
ER0 to ER32767
(ER)
Extension file register
ZR0 to ZR10027007
*1
(ZR)
Index register (16 bits) (Z)
Z0 to Z23
Buffer memory
(Intelligent function module)
G0 to G268435455
*3
(G)
Ww
Ww0 to Ww1FFF
Wr
Wr0 to Wr1FFF
Multiple CPU high speed
U3E000000 to
transmission memory
U3E012287
*4
(U3E0)
Multiple CPU high speed
U3E100000 to
transmission memory
U3E112287
*4
(U3E1)
Multiple CPU high speed
U3E200000 to
transmission memory
U3E212287
*4
(U3E2)
Multiple CPU high speed
U3E300000 to
transmission memory
U3E312287
*4
(U3E3)
Motion device (#)
#0 to #108287
Word-specified bit devices
(except timer, long timer,
Setting range of each
counter, long counter,
bit device
retentive timer, and long
retentive timer)
Long timer
LTN0 to LTN2529407
*1*2
(current value) (LTN)
Long counter
LCN0 to LCN4761215
*1
(current value) (LCN)
Long retentive timer
LSN0 to LSN2529407
*1*2
(current value) (LSN)
Index register (32 bits)
ZZ0 to ZZ22
*2
(ZZ)
Index register (32 bits) (LZ)
LZ0 to LZ11
*1
For the maximum number of devices when an extended
SRAM cassette is installed, refer to the following.
MELSEC iQ-R CPU Module User's Manual
(Application)
*2
Monitoring or writing is not possible in the continuous device
designation mode.
*3
Only the intelligent function module on the station connected
to GOT can be specified.
Set the buffer memory within the address range of the buffer
memory existing in the intelligent function module.
*4
For monitoring the multiple CPU high speed transmission
memory, the CPU buffer memory access device (HG) for
RCPU is monitored.
The CPU buffer memory access device (G) is not monitored.
*5
Only reading is possible.
Device No.
Setting range
representation
Decimal
number
Hexadecimal
number
Decimal
number
-
Decimal
number

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents