Mitsubishi Electric GT1685 Connection Manual page 648

Got1000 series
Table of Contents

Advertisement

(2) FCU6-EX878 (Coaxial cable)
Switch layout
*1
Set the network type to the PLC to PLC network.
*2
Set as necessary.
*3
Set the station No. not to overlap with that of other units.
*4
Set the station type to the control station.
For details of the parameter setting, refer to the following.
18 - 18
18. CNC CONNECTION
18.5 CNC Side Settings
No.
Switch name
Condition setting
switch
8
7
6
5
1)
4
3
2
1
ON
1)
Station number
2)
setting switch
3)
2)
4)
Setting switch of
group number
3)
Setting switch of
network number
5)
4)
Mode setting switch
5)
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
Set the operation condition.
SW
Description
*1
1
Network type
*4
2
Station type
*2
3
Used parameter
4
*2
Number of stations
(Valid when SW3 is ON)
5
6
*2
B/W total points
(Valid when SW3 is ON)
7
8
Not used
*2*3
Station number setting
(Setting range)
01 to 64: Station number
Other than 01 to 64: Setting error
Group number setting
Not used, fixed to 0
*2
Network number setting
(Setting range)
001 to 255: Network number
Other than 001 to 255: Setting error
*2
Mode setting
0: Online
1: Cannot be used
2: Offline
3 to F: Test mode
Settings
OFF
ON
Inter-PC net (PC)
Remote I/O net
Normal station (N.ST)
Control station (MNG)
Common parameters
Default parameter
(PRM)
(D.PRM)
OFF
8
ON
16
OFF
Sta
Sta
tio
tio
OFF
OFF
ON
n
n
OFF
2K
ON
4K
OFF
poi
poi
OFF
OFF
ON
nts
nts
Always OFF
32
ON
64
Sta
Sta
tio
tio
ON
n
n
6K
ON
8K
poi
poi
ON
nts
nts

Hide quick links: