Mitsubishi Electric GT1685 Connection Manual page 611

Got1000 series
Table of Contents

Advertisement

Device
Item
name
Servo states when alarm occurs Oscillation
ALM45
detection frequency
Servo states when alarm occurs Number of
ALM46
tough drives
ALM
For manufacturer setting
47 to 50
Servo states when alarm occurs Unit power
ALM51
consumption 1 (incremwnt of 1 W)
Servo states when alarm occurs Unit total
ALM52
power consumption 1 (incremwnt of 1 Wh)
Alarm number from Alarm History most
ALM200
recent alarm
Alarm number from Alarm History 1st alarm in
ALM201
past
Alarm number from Alarm History 2nd alarm
ALM202
in past
Alarm number from Alarm History 3rd alarm
ALM203
in past
Alarm number from Alarm History 4th alarm
ALM204
in past
Alarm number from Alarm History 5th alarm
ALM205
in past
Alarm number from Alarm History 6th alarm
ALM206
in past
Alarm number from Alarm History 7th alarm
ALM207
in past
Alarm number from Alarm History 8th alarm
ALM208
in past
Alarm number from Alarm History 9th alarm
ALM209
in past
Alarm number from Alarm History 10th alarm
ALM210
in past
Alarm number from Alarm History 11th alarm
ALM211
in past
Alarm number from Alarm History 12th alarm
ALM212
in past
Alarm number from Alarm History 13th alarm
ALM213
in past
Alarm number from Alarm History 14th alarm
ALM214
in past
Alarm number from Alarm History 15th alarm
ALM215
in past
Alarm occurrence time in alarm history most
ALM220
recent alarm
Alarm occurrence time in alarm history 1st
ALM221
alarm in past
Alarm occurrence time in alarm history 2nd
ALM222
alarm in past
Alarm occurrence time in alarm history 3rd
ALM223
alarm in past
Alarm occurrence time in alarm history 4th
ALM224
alarm in past
Alarm occurrence time in alarm history 5th
ALM225
alarm in past
Alarm occurrence time in alarm history 6th
ALM226
alarm in past
Alarm occurrence time in alarm history 7th
ALM227
alarm in past
Alarm occurrence time in alarm history 8th
ALM228
alarm in past
Alarm occurrence time in alarm history 9th
ALM229
alarm in past
Alarm occurrence time in alarm history 10th
ALM230
alarm in past
Alarm occurrence time in alarm history 11th
ALM231
alarm in past
Alarm occurrence time in alarm history 12th
ALM232
alarm in past
Device
Symbol
name
ALM233
ALM234
ALM235
*1
ALM240
*1
ALM241
*1
ALM242
*1
ALM243
*1
ALM244
*1
ALM245
*1
ALM246
*1
ALM247
*1
ALM248
*1
ALM249
*1
ALM250
*1
ALM251
*1
ALM252
*1
ALM253
*1
ALM254
*1
ALM255
*1
The MELSERVO-JE series is equivalent to the MELSERVO-
J4 series, but they are different in parameter functions.
When using the MELSERVO-JE series, refer to the
following.
(o) Machine diagnosis data
Device
name
MD0
MD1
MD2
MD3
MD4
MD5
MD6
MD7
MD8
MD9
MD10
MD11
16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
Item
Alarm occurrence time in alarm history 13th
alarm in past
Alarm occurrence time in alarm history 14th
alarm in past
Alarm occurrence time in alarm history 15th
alarm in past
Detailed alarm from Alarm History most
recent alarm
Detailed alarm from Alarm History 1st alarm
in past
Detailed alarm from Alarm History 2nd alarm
in past
Detailed alarm from Alarm History 3rd alarm
in past
Detailed alarm from Alarm History 4th alarm
in past
Detailed alarm from Alarm History 5th alarm
in past
Detailed alarm from Alarm History 6th alarm
in past
Detailed alarm from Alarm History 7th alarm
in past
Detailed alarm from Alarm History 8th alarm
in past
Detailed alarm from Alarm History 9th alarm
in past
Detailed alarm from Alarm History 10th alarm
in past
Detailed alarm from Alarm History 11th alarm
in past
Detailed alarm from Alarm History 12th alarm
in past
Detailed alarm from Alarm History 13th alarm
in past
Detailed alarm from Alarm History 14th alarm
in past
Detailed alarm from Alarm History 15th alarm
in past
Technical manual for the MELSERVO-JE series
servo amplifiers
Item
Machine diagnosis data parameter number
Machine diagnosis data shift judgment
(test mode)
Machine diagnosis data status
Machine diagnosis data coulomb friction
torque in positive direction
Machine diagnosis data friction torque at
rated speed in positive direction
Machine diagnosis data coulomb friction
torque in negative direction
Machine diagnosis data friction torque at
rated speed in negative direction
Machine diagnosis data oscillation frequency
(motor is stopped)
Machine diagnosis data vibration level
(motor is stopped)
Machine diagnosis data oscillation frequency
(motor is operating)
Machine diagnosis data vibration level
(motor is operating)
Machine diagnosis data rated speed
9
Symbol
10
11
12
13
14
Symbol
15
16
16 - 47