4.
Double-click [Serial USB] of the PC side I/F to display
[PC side I/F Serial Setting].
5.
Check-mark either of the following in [PC side I/F
Serial Setting].
When connecting the GOT and PC with serial
Mark the [RS-232C] checkbox.
When connecting the GOT and PC with USB
Mark the [USB] checkbox.
6.
Double-click [GOT] of the PLC side I/F to display
[PLC side I/F Detailed Setting of GOT].
7.
On the [PLC side I/F Detailed Setting of GOT], mark
the [via GOT(Ethernet) transparent mode] checkbox
and click [Setting...].
8.
By clicking [Set], the [GOT (Ethernet) transparent
setting] is displayed.
Here, set the [FX3U-ENET-ADP] or [Ethernet
Module], which is connected via a GOT.
9.
Set [FX3U-ENET-ADP] or [Ethernet Module] for [PLC
Type].
10.
Specify the IP address for [IP address] same as the
IP address assigned to the [FX3U-ENET-ADP] or
[Ethernet Module].
11.
The screen returns to [Transfer Setup]. Click
[Connection Test] to check if GX Developer has been
connected to the FXCPU.
23. FA TRANSPARENT FUNCTION
23.6 Personal Computer Side Setting
17
18
19
20
21
22
23
23 - 61