Device SP122
0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0
b15
Write 1 to the bits of device SP122 that correspond to the
Forward rotation command (WS1) and Low speed
operation command (WS3).
In this example, device SP122 must store 000AH.
Convert 000AH to a decimal value (10), and then write 10
to device SP122.
• Setting the JOG operation command (WS8), Selection of
automatic restart after instantaneous power failure
command (WS9), Start self-holding selection command
(WS10), and Reset command (WS11)
When setting the above commands, write values to device
SP121 as necessary. As shown in the figure below, each
operation mode is assigned to a bit of device SP121. The
following shows an example of setting the Reset
command (WS11).
Device SP121
0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0
b15
Write 1 to the bit of device SP121 that corresponds to the
Reset command (WS11). In this example, device SP121
must store 0800H. Convert 0800H to a decimal value
(2048), and then write 2048 to device SP121.When using
a WS device, [Alternate] of a bit switch cannot be used.
Use [Momentary], [Set], and [Reset] for bit switch actions.
When using a WS device, [Alternate] of a bit switch cannot
be used.
Use [Set], [Reset], and [Momentary] of a bit switch.
The following shows correspondences between virtual
inverter devices used in the GOT and data of the
inverter.
(1) Inverter status monitor
An example with FREQROL-A700 series is shown
below. For the setting items of other than the
FREQROL-A700 series, refer to the following manual.
User's Manual of the used inverter
(communication function (setting item and set
data))
RS0
RS1
RS2
RS3
RS4
RS5
RS6
RS7
b7
b0
RS8
RS9
RS10
RS11
RS12
RS13
RS14
RS15
(2) Run command
WS0
WS1
WS2
WS3
WS4
b7
b0
WS5
WS6
WS7
WS8
WS9
WS10
WS11
WS12
WS13
WS14
WS15
Device name
Inverter running (RUN)
Forward rotation (STF)
Reverse rotation (STR)
Up to frequency (SU)
Overload (OL)
Instantaneous power failure (IPF)
Frequency detection (FU)
Fault (ABC1)
ABC2
-
-
-
-
-
-
Fault occurrence
*1
The description (function of input terminal) may be changed
by the parameter of the inverter side. Check the function of
the inverter used.
Inverter User's Manual (Application) Communication
operation and setting
An example with FREQROL-A700 series is shown
below. For the setting items of other than the
FREQROL-A700 series, refer to the following manual.
User's Manual of the used inverter
(Communication function (Setting item and set
data))
Device name
Current input selection (AU)
Forward rotation command (STF)
Reverse rotation command (STR)
Low speed operation command (RL)
Middle speed operation command (RM)
High speed operation command (RH)
Second function selection (RT)
Output stop (MRS)
*2
Jog operation (JOG)
Selection of automatic restart after instantaneous
*2
power failure (CS)
*2
Start self-holding (STOP)
*2
Reset (RES)
-
-
-
-
*1
The data (function of input terminal) may be changed by the
parameter of the inverter side. Check the function of the
inverter used.
Inverter User's Manual (Application) Communication
operation and setting
15. INVERTER CONNECTION
15.6 Device Range that Can Be Set
*1
Description
*1
Description
15 - 51
9
10
11
12
13
14
15
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents