HP Indigo Division Series Instruction For Use & Installation Instructions page 133

Table of Contents

Advertisement

Proc.
Electrical cabinet M1
10.
Switch the following circuit breakers and power isolators ON:
a.
22Q5
b.
22Q3
c.
26F1
11.
Switch the following circuit breakers ON:
a.
15F1
b.
15F3
c.
15F1.1
d.
15F3.1
Verify that the voltage between the Pins is 230V.
Note: For each of the following tests, the Connections are 3 x 400V + N + G.
The Neutral and Phase should also be checked against Ground.
12.
Turn the circuit breakers11F6 and 11G6 on.
13.
Turn the circuit breakers 20F8 and 24F1 on.
Make sure that the Cabinet Fan works correctly
Make sure that the Power Supply (20G8) green LED is ON
14.
Turn the circuit breakers20F8.1 on
Make sure that the PLC LEDs are lit
The I/O (60A0 – 60A2) LEDs do not light at this stage.
15.
Turn the following circuit breakers on:
a.
20F3.1
b.
43F1
c.
22F7
16.
Check that the Emergency LEDs at 33K8, 33K9, 33K10,
33K11 switch on:
a.
Turn the Emergency OFF then on.
b.
Press Control on.
c.
Make sure that the LED at 33K0 is lit.
17.
At the ILP touch screen panel
Verify that the Emergency Buttons and Control on buttons
work correctly
18.
At the unwinder touch screen panel
Verify that the Emergency Buttons and Control on buttons
work correctly
19.
At the engines screen
Insert Technical Bypass keys to the Interlocks.
20.
Verify that the Relay 73K6 is on at the PLC.
CA294-03070 rev 00
Installation Manual
Notes
Make sure that the LEDs at the
front of the Mains Cabinet M1
remain lit.
Single phase emergency power
supply.
24V Power Supply
For all Electrical cabinets
24V Power Supply
For both electrical cabinets
(Figure 44 and Figure 45)
Emergency LEDs
Make sure the circuit breaker at
11F6.1 is switched on.
Safety
Safety
PLC Relay
page 133 of 153