Figure 69 Aligning the stepping plate to the PE1 front wall

2
3
2
1
Exit-side stepping plate
2
PE1 chassis
3
30 mm from straight edge to PE1 chassis
d.
Remove the cover. Place aside temporarily.
e.
Align the center of the stepping plate rollers with the PE1 input rollers.
f.
Remount the ILP exit cover.
g.
Place a meter ruler or straight bar along the stepping plate front edge, and extend it
to touch PE1 (Figure 69).
h.
Measure the distance between the stepping plate front edge and the PE1 front wall.
The distance should measure 30 mm.
If not, adjust the position of the ILP as necessary.