Figure 56 Connecting the UPS to the PDU

1
Neutral
2
Three phases
3
Main
4
Breaker button
5
Input from PC
1.
Install and connect the UPS cables as follows:
Cable
From end point
CC73A
UPS No. 1 from slave 1 PC
CC74A
UPS No. 2 from slave 2 PC
CC77A
UPS cable from master PC
CC233
Output cable from slave 1 PC
CC234
Output cable from slave 2 PC
CC235
Output cable from master PC
2.
Make sure that the cables are connected between the UPSs, the PEs, and the electrical
cabinets.

Install the writing head

1.
Carefully remove the writing head (P/N CA270-00101) from Box No. 8.
2.
Remove the parameters diskette from the top of the writing head and save the diskette for
later use.
3.
Remove the four screws securing the plate secured to the heater window at the underside of
the writing head.
Remove the plate. Save the plate in case of writing head replacement.
4.
Install the writing head above the scorotron bridge. Refer to the service documentation
Writing Head for further details.
PDU_CONN1
CA294-03070 rev 00
1
2
3
4
5
To end point
RS232 COM (SNMP) port at the 1
RS232 COM (SNMP) port at the 2
RS232 COM (SNMP) port at the 3
st
Input connection at the 1
nd
Input connection at the 2
rd
Input connection at the 3
Installation Manual
st
UPS
nd
UPS
rd
UPS
UPS
UPS
UPS
page 76 of 153