HP Indigo Division Series Instruction For Use & Installation Instructions page 134

Table of Contents

Advertisement

Proc.
Electrical cabinet M1
21.
At the unwinder
Close all doors and Covers and make sure that the Control on
button works correctly
22.
Check the Unidrive connections at 24F1- 29F1
Make sure that the Boards are inserted correctly
23.
Check the Unidrive connections at 24U0
Make sure that the Boards are inserted correctly
24.
Make sure that the Unidrives turn on
Proc.
Electrical cabinet M2
Note: For each of the following tests, the Connections are 3 x 400V + N + G.
The Neutral and Phase should also be checked against Ground.
25.
Turn the circuit breaker 20F8 on
Make sure that the Cabinet Fan works correctly
Make sure that the Power Supply (20G8) green LED is on
26.
Turn the circuit breakers20F8.1 on
Make sure that the PLC LEDs are lit
The I/O (60A0 – 60A2) LEDs do not light at this stage.
27.
Turn the following circuit breakers on:
a.
20F3.1
b.
43F1
c.
22F7
28.
Check the Unidrive connections at VB2- FX
Make sure that the Boards are inserted correctly
Turn the Unidrives on
29.
Turn the following circuit breakers on:
a.
11Q3
b.
11Q5
30.
Turn the following Unidrive circuit breakers on:
a.
24F1
b.
25F1
c.
26F1
d.
27F1
e.
28F1
f.
29F1
31.
Turn the printing engines main power on.
CA294-03070 rev 00
Installation Manual
Notes
Notes
24V Power Supply
For all Electrical cabinets
24V Power Supply
For both electrical cabinets
(Figure 44 and Figure 45)
Inverter VB2
Inverter VBX
Controls:
Unidrive FP1
Unidrive IP1
Unidrive FP2
Unidrive IP2
Unidrive FE
Unidrive FX
page 134 of 153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W3250

Table of Contents