Figure 64 Distinguishing The Ilp Feed And Exit Stepping Plate Assemblies - HP Indigo Division Series Instruction For Use & Installation Instructions

Table of Contents

Advertisement

13
Idler No. 14
14
Idler No. 15
15
Idler No. 12
16
Idler No. 11
The following ILP installation procedure is performed (Figure 63):
1.
Install the exit stepping plate.
2.
Set the ILP close to its final position.
3.
Raise the ILP 5 mm above the ground.
4.
Adjust the ILP to its final position (level and parallelism).
5.
Install the feed stepping plate
6.
Adjust the feed and exit stepping plates.
7.
Install the unwinder.
8.
Install all cables to/from the Electrical cabinet M1, ILP and unwinder.
Positioning the ILP
1.
Move the ILP on the floor platform to the input side of PE1.
The ILP should be supported by its castors enabling it to be rolled into position.

Figure 64 Distinguishing the ILP feed and exit stepping plate assemblies

1
ILP feed stepping plate assembly
2
Connecting studs
3
Front section connected to ILP feed
4
Gas spring arm
5
Holes for ILP exit cover securing pins
29
30
31
6
Front section connected to PE1 feed
7
Holes for ILP exit cover securing pins
8
Gas spring arm
9
ILP exit stepping plate assembly
CA294-03070 rev 00
Inner station duplex primer No. 3 (DP3)
Inner station duplex primer No. 4 (DP4)
Idler No. 6
Installation Manual
page 82 of 153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W3250

Table of Contents