Troubleshooting
Step 5. Verify that the proper software version is highlighted and press Enter.
When Caution appears on the screen with the message If you continue, your Firmware
will be Reprogrammed:
Step 6. Press Enter to program the device.
Note
Do not reboot or power cycle the device until the programming is complete.
When Flash Programming Completed Successfully appears on the screen with the
message Reboot Now for the new System ROM to take effect:
Step 7. Press Enter.
When the question Do you want to reprogram another ROM appears:
Step 8. Press the keyboard Esc key to Exit the program.
Step 9. Remove the Recovery BIOS Floppy Disk from the A: drive and place it in its
Step 10. Perform the System Setup procedure for the "ML370 G3 Database Server" on
ML370 G2
Step 1. Insert the Recovery BIOS Floppy Disk into the A: drive of the Server.
Step 2. Properly shutdown and power cycle the Server to reboot it.
When Welcome to ROMPAQ appears on the screen:
Step 3. Press Enter to display the Select a Device window.
Step 4. Verify that Compaq Proliant ML370 G2 is highlighted in the List of
When Select an Image appears on the screen:
Step 5. Verify that the proper software version is highlighted and press Enter.
When Caution appears on the screen with the message If you continue, your Firmware
will be Reprogrammed:
Step 6. Press Enter to program the device.
Note
Do not reboot or power cycle the device until the programming is complete.
When the question Do you want to reprogram another device appears:
Step 7. Press the keyboard Esc key to Exit the program.
Step 8. Remove the Recovery BIOS Floppy Disk from the A: drive and place it in its
Step 9. Perform the System Setup procedure for the "ML370 G2 Database Server" on
7-120
Maintenance, Troubleshooting, and Repair
holder on the side of the Server the PC.
page 7-122.
Upgradeable Devices and press Enter. The message Please Wait appears.
holder on the side of the Server the PC.
page 7-124.