Download Print this page

Toshiba GR200 Series Instruction Manual page 899

Hide thumbs Also See for GR200 Series:

Advertisement

Operating state
Selection signal for Device #2
Selection signal for Device #3
Selection signal for Device #1
Figure 4.11-4 Time chart of automatic sequence when emergency stop command is applied
Control hierarchy conditions
4.11.4
The user should program the "Control hierarchy" for the ASEQ01 function. The user should
connect the condition with the select condition logic using the connection point
"ASEQ01IN_TMP_28". For more information, see Chapter
Control hierarchy
Table 4.11-8 Control hierarchy points on ASEQ functions
Signal Number
523001 820D01ED50
523001 820D02ED50
523001 820D03ED50
...
523001 820D0FED50
Table 4.11-9 Control hierarchy point for Emergency stop
Signal Number
523001 820D10ED50
Input for emergency stop
4.11.5
The ASEQ functions are able to receive an "EMERSTOP_EXEC_STOP" command (see Table
4.11-3); the user should program to acquire the sign so that the ASEQ logics can abandon for
controlling devices. The operation will stop instantly even if the control logic is waiting for
some condition (i.e., synchronization or others).
Table 4.11-10 PLC monitoring points (Outputs for ASEQ emergency status)
Signal Number
523001 000D0D1001
523001 800D0D1D58
523001 800D0D1D55
523001 800D0D1D56
523001 800D0D1D57
ON
*
4
The operation state turns to OFF, when the control logic cancels the
selection of Device#1 following the reception of a stop command from
the ASEQ01 function.
during the operation of Device#1
. Table 4.11-8 shows the respective points in the ASEQ functions.
Signal Name
ASEQ01IN_TMP_28
ASEQ02IN_TMP_28
ASEQ03IN_TMP_28
...
ASEQ15IN_TMP_28
Signal Name
EMERSTOPIN_TMP_28
Signal Name
EMERSTOP_ACC_EXEC
EMERSTOP_EC_LCD
EMERSTOP_EC_OWS
EMERSTOP_EC_RCC
EMERSTOP_EC_RMT
- 878 -
*
3
signal to OFF when the control signal is
not sent for the device.
*
2
The ASEQ01 function generates an emergency
command for the control logic.
*
1
The ASEQ01 function generates a selection signal for
the emergency stop for the control logic.
Control and monitoring application:
Description
ASEQ01 control hierarchy condition
ASEQ02 control hierarchy condition
ASEQ03 control hierarchy condition
...
ASEQ15 control hierarchy condition
Description
Emergency control for stopping the operation
Description
Reception of an emergency signal
Emergency signal generated on the LCD scream
Emergency signal generated from OWS(HMI)
Emergency signal generated from RCC
Emergency signal generated at Remote
6F2S1915 (0.46)
OFF
The control logic turns the selection
M/O
M
M
M
M
M/O
M
GRZ200 (Soft 031 & 032)

Advertisement

loading

This manual is also suitable for:

Grz200