Setting
4.9.8
TPOS01(FunctionID:513001)
Setting items
Commo n
TPOS-NELD
TPOS-TELD
TPOS-TELR
TPOS01-EN
Dev01
TPOS01-DEVNAME
TPOS01-000NAME
TPOS01-001NAME
TPOS01-010NAME
TPOS01-011NAME
TPOS01-100NAME
TPOS01-101NAME
TPOS01-110NAME
TPOS01-111NAME
TPOS01-UDFNAME
TPOS01-FLTNAME
TPOS01-DEVTYPE
TPOS01-P1NOPSG
TPOS01-P1NOPSGI
TPOS01-P2NOPSG
TPOS01-P2NOPSGI
TPOS01-P3NOPSG
TPOS01-P3NOPSGI
TPOS01-SPPEN
TPOS01-UDFEN
TPOS01-UDFTIM
TPOS01-FLTEN
TPOS01-FLTTIM
TPOS01-CTREN
TPOS01-CTRMENU
TPOS01-CTRAHMI
TPOS01-NSLBORD1
TPOS01-NSLBORD2
TPOS01-NSLBORD3
TPOS01-P1SLBORD
TPOS01-P2SLBORD
TPOS01-P3SLBORD
TPOS01-P1EXBORD
TPOS01-P2EXBORD
TPOS01-P3EXBORD
TPOS01-LGCTRCON
Range
Unit
0 - 99
- Number of Event lock detect time
1 - 99
s Timer of detect event lock
1 - 99
s Timer of recovery from event lock
Off / On
- TPOS01 switch for Device01
[Preferred text] - item name of TPOS_Dev1
[Preferred text] - state name of (0,0,0)state
[Preferred text] - state name of (0,0,1)state
[Preferred text] - state name of (0,1,0)state
[Preferred text] - state name of (0,1,1)state
[Preferred text] - state name of (1,0,0)state
[Preferred text] - state name of (1,0,1)state
[Preferred text] - state name of (1,1,0)state
[Preferred text] - state name of (1,1,1)state
[Preferred text] - state name of undefined
[Preferred text] - state name of faulty
switch / EDS
- Device Type
- P1 Normally Open Signal of Dev1
[Preferred signal]
Off / On
- Signal inverse or not
- P2 Normally Open Signal of Dev1
[Preferred signal]
Off / On
- Signal inverse or not
- P3 Normally Open Signal of Dev1
[Preferred signal]
Off / On
- Signal inverse or not
Off / On
- Automatic event suppression function
Off / On /
- undefined pallet check function
CHKONLY
0.1 - 100.0
s palette undefined check timer
Off / On /
- faulty pallet check function
CHKONLY
0.1 - 100.0
s palette faulty check timer
Off / On
- control mode (control enable)
Off / On
- control by MENU enable
DIR / SBO
- control action(Direct or SBO)by HMI
select binary output read data(DataID)1 for no
-
[Preferred signal]
direction command
select binary output read data(DataID)2 for no
-
[Preferred signal]
direction command
select binary output read data(DataID)3 for no
-
[Preferred signal]
direction command
select binary output read data(DataID) for P1
-
[Preferred signal]
direction command
select binary output read data(DataID) for P2
-
[Preferred signal]
direction command
select binary output read data(DataID) for P3
-
[Preferred signal]
direction command
execute binary output read data(DataID) for
-
[Preferred signal]
P1 direction command
execute binary output read data(DataID) for
-
[Preferred signal]
P2 direction command
execute binary output read data(DataID) for
-
[Preferred signal]
P3 direction command
FixedLogic /
- Change logic about control condition
PLC
- 857 -
6F2S1915 (0.46)
Contents
GRZ200 (Soft 031 & 032)
Default
Note
10
10
10
Off
TPOS_Dev1
!
Travelling0
!
P1
!
P2
!
Travelling1
!
P3
!
Travelling2
!
Travelling3
!
Travelling4
!
Undefine
!
Faulty
!
switch
Not assigned
Off
Not assigned
Off
Not assigned
Off
Off
Off
30.0
Off
30.0
Off
Off
SBO
5130018904011DC0
5130018904011DC0
5130018904011DC0
5130018A04011DC4
5130018A04011DC6
5130018A04011DC8
Not assigned
Not assigned
Not assigned
FixedLogic