Connection point in PLC logic
ARC(Function ID: 4A6001)
Element ID
Name
810002EBB7
ARC2_BLOCK
810002EBB1
ARC2_MODE-FT
800002EBB0
ARC2_MODE-OFF
860002EBB6
ARC2_MODE-ORG
840002EBB4
ARC2_MODE-S&T
820002EBB2
ARC2_MODE-SPAR
830002EBB3
ARC2_MODE-TPAR
820000EBB4
ARC_BLOCK
800001EBB8
CB1 F.BRIDGE
800001EBB7
CB1-ARC READY
800001EBCD
CB1_MANUAL_CLOSE
810002EBB9
CB2 F.BRIDGE
810002EBB8
CB2-ARC READY
810002EBCA
CB2_MANUAL_CLOSE
800000EBB0
EXT.ARC_START-A
810000EBB1
EXT.ARC_START-B
820000EBB2
EXT.ARC_START-C
800001EBCE
F.CB1_94TT
810002EBCB
F.CB2_94TT
820001EBC2
ORGAR1_COND
820001EBC1
ORGAR1_START
820001EBC4
ORGAR1_SUB_COND
820001EBC3
ORGAR1_SUB_START
820002EBC3
ORGAR2_COND
820002EBC2
ORGAR2_START
820002EBC5
ORGAR2_SUB_COND
820002EBC4
ORGAR2_SUB_START
800000EBB5
RYOP-A
810000EBB6
RYOP-B
820000EBB7
RYOP-C
800001EBBA
SPAR1_COND
800001EBB9
SPAR1_START
800001EBBC
SPAR1_SUB_COND
800001EBBB
SPAR1_SUB_START
800002EBBB
SPAR2_COND
800002EBBA
SPAR2_START
800002EBBD
SPAR2_SUB_COND
800002EBBC
SPAR2_SUB_START
810001EBBE
TPAR1_COND
810001EBBD
TPAR1_START
810001EBC0
TPAR1_SUB_COND
810001EBBF
TPAR1_SUB_START
810002EBBF
TPAR2_COND
810002EBBE
TPAR2_START
Description
ARC2 block signal
Final trip mode for autoreclose 2
Off mode for autoreclose 2
Original mode for autoreclose 2
Single and three-phase mode for autoreclose 2
Single-phase mode for autoreclose 2
Three-phase mode for autoreclose 2
ARC1 & ARC2 block signal
Forcible bridge signal for CB1
CB1 ready signal for ARC1
CB1 manual close siganl
Forcible bridge signal for CB2
CB2 ready signal for ARC2
CB2 manual close siganl
External ARC start signal (phase-A)
External ARC start signal (phase-B)
External ARC start signal (phase-C)
Forcible discrepancy trip signal in CB1
Forcible discrepancy trip signal in CB2
For original ARC1 condition
For original ARC1 start
For original ARC1 condition (sub)
For original ARC1 start (sub)
For original ARC2 condition
For original ARC2 start
For original ARC2 condition (sub)
For original ARC2 start (sub)
Relay operation (phase-A)
Relay operation (phase-B)
Relay operation (phase-C)
For single-phase ARC1 condition
For single-phase ARC1 start
For single-phase ARC1 condition (sub)
For single-phase ARC1 start (sub)
For single-phase ARC2 condition
For single-phase ARC2 start
For single-phase ARC2 condition (sub)
For single-phase ARC2 start (sub)
For three-phase ARC1 condition
For three-phase ARC1 start
For three-phase ARC1 condition (sub)
For three-phase ARC1 start (sub)
For three-phase ARC2 condition
For three-phase ARC2 start
- 376 -
6F2S1915 (0.46)
GRZ200 (Soft 031 & 032)