Download Print this page

Toshiba GR200 Series Instruction Manual page 392

Hide thumbs Also See for GR200 Series:

Advertisement

Setting
2.24.6
Autoreclose setting (Function ID:441001)
Setting device
ARC1-EN
ARC2-EN
MultiShot-EN
Comm
ARC1-MODE
ARC2-MODE
MPAR-MODE
ARC-MANOLK
ARC-ORDER
ARC-NUM
ARC-SucChk
FT-3pFault
TRESET
TEVLV
CHK
TARCSUC
ARC1
TREADY1
TSPAR1
TSPAR1_SUB
TTPAR1
TTPAR1_SUB
TMPAR1
TMPAR1_SUB
TORGAR1
TORGAR1_SU
B
TRR1
TCCW1
ARC2
TREADY2
TSPAR2
TSPAR2_SUB
TTPAR2
TTPAR2_SUB
TMPAR2
TMPAR2_SUB
TORGAR2
TORGAR2_SU
B
TRR2
TCCW2
Multi
TD_MS2
TRR_MS2
TD_MS3
TRR_MS3
TD_MS4
TRR_MS4
TD_MS5
TRR_MS5
†MPAR mode is not available in GRZ200 relay.
Range
Unit
1A rating
5A rating
Off / On
- ARC1 scheme switch
Off / On
- ARC2 scheme swtich
Off / On
-
Off / FT / SPAR /
TPAR / SPAR&TPAR /
- Auto reclose mode in 1CB-system
MPAR
/ Original
Off / FT / SPAR /
Auto reclose mode of Center-CB in 2CB-
TPAR / SPAR&TPAR /
-
system
MPAR
/ Original
M2 / M3
- Multi phase autoreclose mode
FT / TPAR /
ARC operation in multi phase ARC NO-LINK
-
SPAR&TPAR
condition
SIMUL / CB1 / CB2
- Turn of the 3-phase autoreclosing circuit start
S1 / S2 / S3 / S4 / S5
- Auto reclose maximum shot number
Off / On
- Autoreclose success checking enable
Off / On
- Execute final trip in 3-phase fault mode
0.01 - 300.00
s Autoreclose reset time under CB closed
0.01 - 300.00
s Evolving fault waiting time
0.10 - 100.00
s Autoreclose success checking time
0.0 - 600.0
s Autoreclose1 ready check time
0.01 - 300.00
s Autoreclose1 SPAR dead time
0.01 - 300.00
s Autoreclose1 sub-SPAR dead time
0.01 - 300.00
s Autoreclose1 TPAR dead time
0.01 - 300.00
s Autoreclose1 sub-TPAR dead time
0.01 - 300.00
s Autoreclose1 MPAR dead time
0.01 - 300.00
s Autoreclose1 sub-MPAR dead time
0.01 - 300.00
s Autoreclose1 user original ARC dead time
0.01 - 300.00
s Autoreclose1 sub user original ARC dead time
0.01 - 310.00
s Autoreclose1 reset time
0.01 - 10.00
s Autoreclose1 ARC command pulse width
0.0 - 600.0
s Autoreclose2 ready check time
0.01 - 300.00
s Autoreclose2 SPAR dead time
0.01 - 300.00
s Autoreclose2 sub-SPAR dead time
0.01 - 300.00
s Autoreclose2 TPAR dead time
0.01 - 300.00
s Autoreclose2 sub-TPAR dead time
0.01 - 300.00
s Autoreclose2 MPAR dead time
0.01 - 300.00
s Autoreclose2 sub-MPAR dead time
0.01 - 300.00
s Autoreclose2 user original ARC dead time
0.01 - 300.00
s Autoreclose2 sub user original ARC dead time
0.01 - 310.00
s Autoreclose2 reset time
0.01 - 10.00
s Autoreclose2 ARC command pulse width
0.01 - 300.00
s 2nd shot ARC dead time
0.01 - 310.00
s 2nd shot ARC reset time
0.01 - 300.00
s 3rd shot ARC dead time
0.01 - 310.00
s 3rd shot ARC reset time
0.01 - 300.00
s 4th shot ARC dead time
0.01 - 310.00
s 4th shot ARC reset time
0.01 - 300.00
s 5th shot ARC dead time
0.01 - 310.00
s 5th shot ARC reset time
- 371 -
6F2S1915 (0.46)
Contents
GRZ200 (Soft 031 & 032)
Default
Note
1A
5A
Off
Off
Off
Off
Off
M2
FT
SIMUL
S1
On
Off
0.30
0.30
0.30
60.0
0.80
300.00
0.60
300.00
1.00
300.00
300.00
300.00
2.00
0.20
60.0
0.80
300.00
0.60
300.00
1.00
300.00
300.00
300.00
2.00
0.20
20.00
30.00
20.00
30.00
20.00
30.00
20.00
30.00