Signal monitoring point
ZS (Function ID: 430001)
Element ID
8500051BB3
8800051B6A
8900051B6B
8A00051B6C
8500051B2B
8C00001B66
8D00001B67
8E00001B68
8300001B2B
8000011C20
8000011B60
8000011B69
8100011C21
8100011B61
8200011C22
8200011B62
8000011B23
8000011B66
8100011B67
8200011B68
8300011B63
8000011BB0
8000011BB2
8000011BB1
8300011B65
8400061C20
8400061B60
8100061B69
8500061C21
8500061B61
8600061C22
8600061B62
8100061B23
8400061B66
8500061B67
8600061B68
8700061B63
8100061BB0
8100061BB2
8100061BB1
8700061B65
8000021C20
8000021B60
8200021B69
Name
Description
SOTF-Z5S BLOCK
SOTF block signal for Z5S
SOTF-Z5S-OPT-AB
SOTF operated for Z5S (phase-AB)
SOTF-Z5S-OPT-BC
SOTF operated for Z5S (phase-BC)
SOTF-Z5S-OPT-CA
SOTF operated for Z5S (phase-CA)
SOTF-Z5S-TRIP
SOTF operated for Z5S (3-phases OR)
SOTF-ZS-OPT-ABR
SOTF AB phase operated
SOTF-ZS-OPT-BCR
SOTF BC phase operated
SOTF-ZS-OPT-CAR
SOTF CA phase operated
SOTF-ZS-TRIP
SOTF protection trip
Z1S-AB
Z1S relay element operated (phase-AB)
Z1S-ABX
Z1S-ABX operated (phase-AB)
Z1S-ARC-BLOCK
Autoreclose block by Z1S protection
Z1S-BC
Z1S relay element operated (phase-BC)
Z1S-BCX
Z1S-BCX operated (phase-BC)
Z1S-CA
Z1S relay element operated (phase-CA)
Z1S-CAX
Z1S-CAX operated (phase-CA)
Z1S-OPT
Z1S operated (3-phases OR)
Z1S-OPT-AB
Z1S operated (phase-AB)
Z1S-OPT-BC
Z1S operated (phase-BC)
Z1S-OPT-CA
Z1S operated (phase-CA)
Z1S-ORX
Z1S-X operation level pick up (3-phases OR)
Z1STP_BLOCK
Z1S trip block signal
Z1S_ARCBLOCK
Autoreclose block signal for Z1S
Z1S_INST_OP
Z1S instantaneously operated
Z1S_ORX OP
Z1S operated before timer (3-phases OR)
Z1XS-AB
Z1XS relay element operated (phase-AB)
Z1XS-ABX
Z1XS-ABX operated (phase-AB)
Z1XS-ARC-BLOCK
Autoreclose block by Z1XS protection
Z1XS-BC
Z1XS relay element operated (phase-BC)
Z1XS-BCX
Z1XS-BCX operated (phase-BC)
Z1XS-CA
Z1XS relay element operated (phase-CA)
Z1XS-CAX
Z1XS-CAX operated (phase-CA)
Z1XS-OPT
Z1XS operated (3-phases OR)
Z1XS-OPT-AB
Z1XS operated (phase-AB)
Z1XS-OPT-BC
Z1XS operated (phase-BC)
Z1XS-OPT-CA
Z1XS operated (phase-CA)
Z1XS-ORX
Z1XS-ORX operation level pick up (3-phases OR)
Z1XSTP_BLOCK
Z1XS trip block signal
Z1XS_ARCBLOCK
Autoreclose block signal for Z1XS
Z1XS_INST_OP
Z1XS instantaneously operated
Z1XS_ORX OP
Z1XS operated before timer (3-phases OR)
Z2S-AB
Z2S relay element operated (phase-AB)
Z2S-ABX
Z2S-ABX operated (phase-AB)
Z2S-ARC-BLOCK
Autoreclose block by Z2S protection
- 106 -
6F2S1915 (0.46)
GRZ200 (Soft 031 & 032)