Toshiba GR200 Series Instruction Manual page 546

Hide thumbs Also See for GR200 Series:

Advertisement

Input
Command "Remote-Off-Control"
ILK† condition ("Off") passed
SPOS01-Off
ILK† bypassing
ICB_STATE
User configurable condition (PLC#3 connection point)
510001 800101EE56
SPOS01IN_TMP_34
User configurable condition (PLC#2 connection point)
510001 810101EDDA
SPOS01IN_TMP_42
ASEQ function§" is in progress
ASEQ_MULTI_SEL
Figure 4.1-26 Operate 'Off' on the front panel in SPOS01††
†Note: The ILK function provides the operation criteria for "Off".
‡Note: An "operate condition" signal is generated in the operate-condition logic( see
Figure 4.1-29), when Fixlogic is set for scheme switch [SPOS01-LGCTRCON], If
an alternative "Operate-condition" is required it can be programmed by the user
and used to replace the signal generated by the original operated-condition logic.
The alternative "Operate-condition" can be connected to the above logic using
connection point #3 "User configurable condition". That is, set the scheme switch
[SPOS01-LGCTRCON] to PLC and use SPOS01IN_TMP_34.
§Note: The ASEQ function can provide sequential signals for automatic control.
*Note: The user can set the type of output signal. When Var is set for the scheme switch
[SPOS01-PLSM], the output period of the signal is defined by the setting
[SPOS01-CPW]. When Fix is set, the signal ceases when the 43-switch is changed.
When Latch is set, the output signal is kept issuing until the reception of
"Command Off".
Note: To identify the input and output signal-points of the other SPOS logics, see Table
††
4.1-14, Table 4.1-15, Table 4.1-19, and Table 4.1-20.
Note: The "Operate failed" signal is issued when the state-change is not detected until
‡‡
after reaching the time set by the [SPOS01-RST].
§§Note: The signal "SPOS01_OEX-BO" is issued when Fixlogic is set for scheme switch
[SPOS01-LGCFEXOT]. The "Operate completed" signal can also be issued from
logic programmed by the user in place of the logic shown in Figure 4.1-20. The
Operate logic in SPOS01
SPOS1 function (Function ID: 510001)
Operate Cmd.
with ILK
condition
&
Operation Cmd.
without ILK
condition
1≥
[SPOS01-LGCTRCON]
Fixedlogic
Operate condition‡
[SPOS01-LGCFEXOT]
Fixedlogic
[SPOS01-PLSM]*
Var
Fix
"SPOS01-EX_CMP
(5A0101_8001011E93)
- 525 -
"
SPOS01-FEC_OK_CSF"
(510001_8001011E7F)
1≥
1≥
&
&
&
&
PLC#3
6F2S1915 (0.46)
Output
[SPOS01-CPW]
1≥
0.1 – 50.0 s
S
R
To BO connection
"SPOS01_FEX_BO"
"510001_8101011DD0 §§
&
Assign to BOs
To PLC
&
logic
PLC#2
To "Wait for a command"
"
SPOS01_EX_FFL
"510001_8601011E91 ††
[SPOS01-RST]
0
t
Operation Failed
1.0s- 100.0s
GRZ200 (Soft 031 & 032)
"