Page 1
LOGIQ™ S8 Service Manual ADVANCED SERVICE DOCUMENTATION. PROPERTY OF GE HEALTHCARE. USE OF THESE MATERIALS LIMITED TO AGENTS AND EMPLOYEES OF GE HEALTHCARE OR OTHER PARTIES EXPRESSLY LICENSED BY GE HEALTHCARE. UNLICENSED USE IS STRICTLY PROHIBITED Document Number: 5394227 Revision:...
Page 2
P R E L I M I N A R Y (NOVEMBER 17, 2011) VE6_VE8_COVER.FM GE Healthcare ADVANCED SERVICE DOCUMENTATION. PROPERTY OF GE HEALTHCARE. USE OF THESE MATERIALS LIMITED TO AGENTS AND EMPLOYEES OF GE HEALTHCARE OR OTHER PARTIES EXPRESSLY LICENSED BY GE HEALTHCARE. UNLICENSED USE IS STRICTLY PROHIBITED...
Page 3
• VERSUCHEN SIE NICHT, DAS GERä T ZU REPARIEREN, BEVOR DIESES WARNUNG KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN (DE) WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLä GE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
Page 4
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL ESTE MANUAL DE SERVICIO Só LO EXISTE EN INGLé S. • SI ALGú N PROVEEDOR DE SERVICIOS AJENO A GEHC SOLICITA UN IDIOMA QUE NO SEA EL INGLé S, ES RESPONSABILIDAD DEL CLIENTE OFRECER UN SERVICIO DE TRADUCCIó...
Page 5
ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝΔΥΝΟΥΣ. EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A FIGYELMEZTETÉS KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK.
Page 6
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL ÞESSI ÞJÓNUSTUHANDBÓK ER EINGÖNGU FÁANLEG Á ENSKU. • EF ÞJÓNUSTUAÐILI VIÐSKIPTAMANNS ÞARFNAST ANNARS TUNGUMÁLS EN ENSKU, ER ÞAÐ Á ÁBYRGÐ VIÐSKIPTAMANNS AÐ ÚTVEGA ÞÝÐINGU. • REYNIÐ EKKI AÐ ÞJÓNUSTA TÆKIÐ NEMA EFTIR AÐ HAFA SKOÐAÐ OG VIÐVÖRUN...
Page 7
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL šĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS BRĪDINĀJUMS...
Page 8
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL ACEST MANUAL DE SERVICE ESTE DISPONIBIL NUMAI ÎN LIMBA ENGLEZĂ. • DACĂ UN FURNIZOR DE SERVICII PENTRU CLIENŢI NECESITĂ O ALTĂ LIMBĂ DECÂT CEA ENGLEZĂ, ESTE DE DATORIA CLIENTULUI SĂ FURNIZEZE O TRADUCERE.
Page 9
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL TA SERVISNI PRIROČNIK JE NA VOLJO SAMO V ANGLEŠČINI. • ČE PONUDNIK SERVISNIH STORITEV ZA STRANKO POTREBUJE NAVODILA V DRUGEM JEZIKU, JE ZA PREVOD ODGOVORNA STRANKA SAMA. • NE POSKUŠAJTE SERVISIRATI OPREME, NE DA BI PREJ PREBRALI IN OPOZORILO RAZUMELI SERVISNI PRIROČNIK.
Page 10
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. DİKKAT • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE (TR) ETMEYİNİZ.
Page 11
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL (ZH-CN) (KO)
Page 12
GE Healthcare personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes.
Page 13
The contents of this publication may not be copied or duplicated in any form, in whole or in part, without prior written permission of GE Healthcare. GE Healthcare may revise this publication from time to time without written notice. TRADEMARKS All products and their name brands are trademarks of their respective holders.
Page 14
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Revision History Revision Date Reason for change Jun. 2011 Initial Release Jul. 2011 Correction Sep. 2011 Correction List of Effected Pages (LOEP) Pages Revision Pages Revision Pages Revision Title Page...
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Table of Contents CHAPTER 1 Introduction Overview ............1 - 1 Purpose of Chapter 1 .
Page 16
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 2 Site Preparation Overview ............2 - 1 Purpose of Chapter 2 .
Page 17
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 3 Setup Instructions Overview............3 - 1 The Purpose of Chapter 3 .
Page 18
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Connecting the Probe ........3 - 26 Connecting the CW Pencil Probe .
Page 19
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Removing a service ........3 - 48 Changing parameters for a service .
Page 20
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 4 Functional Checks Overview ............4 - 1 Purpose of Chapter 4 .
Page 21
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL B-Flow Mode ......... . 4 - 24 OPIO Interface Check .
Page 22
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 5 Components and Functions (Theory) Overview ............5 - 1 Purpose of Chapter 5 .
Page 23
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 6 Service Adjustments Overview............6 - 1 Purpose of Chapter 6 .
Page 24
GE Icon and Remote Connection ....... . 7 - 6...
Page 25
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 8 Replacement Procedures Overview............8 - 1 Purpose of Chapter 8 .
Page 26
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Replacement Side Cover ..........8 - 16 Manpower .
Page 27
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Removal Procedure - TGC Assy ......8 - 32 Removal Procedure - LCD Touch Panel Assy .
Page 28
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Removal Procedure ......... . . 8 - 55 Installation Procedure .
Page 29
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Installation Procedure ........8 - 76 Functional Check .
Page 30
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Color Printer ..........8 - 88 Color printer on Mid Console .
Page 31
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Installation Procedure ......... 8 - 100 Functional Check .
Page 32
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 9 Renewal Parts Overview ............9 - 1 Purpose of Chapter 9 .
Page 33
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL CHAPTER 10 Care & Maintenance Overview............10 - 1 Periodic Maintenance Inspections .
Page 34
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Type BF Patient Leakage current - Mains to Probe ....10 - 16...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 1 Introduction Section 1-1 Overview 1-1-1 Purpose of Chapter 1 This chapter describes important issues related to safely servicing the LOGIQ™ S8 ultrasound system.
EVISION OVEMBER ERVICE ANUAL 1-1-3 Typical Users of the Basic Service Manual • GE Service Personnel (installation, maintenance, etc.). • Hospital’s Service Personnel • Contractors (Some parts of Chapter 2 - Pre-Installation) 1-1-4 Models Covered by this Manual Table 1-2 LOGIQ™...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-1-5 Purpose of Operator Manual(s) The Operator Manual(s) should be fully read and understood before operating the LOGIQ™ S8 and also kept near the unit for quick reference.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-2-2 Standard Hazard Icons Important information will always be preceded by the exclamation point contained within a triangle, as seen throughout this chapter. In addition to text, several different graphical icons (symbols) may be used to make you aware of specific types of hazards that could cause harm.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-2-3 Product Icons The following table describes the purpose and location of safety labels and other important information provided on the equipment. Table 1-5...
Page 40
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 1-5 Product Icons (Continued) LABEL/SYMBOL PURPOSE/MEANING LOCATION "CAUTION - Dangerous voltage" (the lightning flash with arrowhead in equilateral triangle) is used to indicate electric various shock hazards.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 1-3 Safety Considerations 1-3-1 Introduction The following safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual, violates safety standards of design, manufacture and intended use of the equipment.
DO NOT attempt to use different peripherals and accessories (brand and model; WARNING WARNING connected via USB ports) other than approved and provided by GE Healthcare! !! WARNING: The ultrasound system is an extremely sensitive and complex medical system. Any unauthorized peripherals may cause system failure or damage! The LOGIQ™...
Page 43
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-3-5 Auxiliary Devices Safety (cont’d) Everybody who connects additional equipment to the signal input portion or signal output portion configures a medical system, and is therefore responsible that the system complies with the requirements of the system standard IEC 60601-1-1.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-3-6 Labels Locations The LOGIQ™ S8 ultrasound system comes equipped with product labels and icons. These labels and icons represent pertinent information regarding the operation of the unit.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-3-6-1 Main Label The Main Label is located on the rear of the LOGIQ™ S8 system. Figure 1-2 Main Label (located on left rear of LOGIQ™ S8)
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-3-7 Dangerous Procedure Warnings Warnings, such as the examples below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1-3-9 Returning/Shipping System, Probes and Repair Parts (cont’d) NOTE: The US Department of Transportation (DOT) has ruled that “items what were saturated and/or dripping with human blood that are now caked with dried blood;...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 2 Site Preparation Section 2-1 Overview 2-1-1 Purpose of Chapter 2 This chapter provides the information required to plan and prepare for the installation of a LOGIQ™ S8 ultrasound unit.
Electrical Requirements NOTE: GE Healthcare requires a dedicated power and ground for the proper operation of its Ultrasound equipment. This dedicated power shall originate at the last distribution panel before the system. The dedicated line shall consist of one phase, a neutral (not shared with any other circuit), and a full size Ground wire from the distribution panel to the Ultrasound outlet.
The LOGIQ™ S8 ultrasound system is supplied with a main power plug, as standard. In the event that the unit arrives without a power plug, or with the wrong plug, contact your GE dealer. When necessary, the installation engineer will supply the appropriate power plug to meet the applicable local regulations.
RF gaskets touch metal. appropriate location. The interconnect cables are grounded and require ferrite beads and other shielding. Use GE- specified Cable length, material, and routing are all important; do not make any changes that do not meet harnesses and peripherals.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 2-2-6 System Specifications 2-2-6-1 Physical Dimensions of LOGIQ™ S8 The physical dimensions and weight (without Peripherals) of the LOGIQ™ S8 unit are summarized in Table 2-6.
The products involved (and the accompanying electrical installations) are highly sophisticated and special engineering competence is required. All electrical work on these products must comply with the requirements of applicable electrical codes. The purchaser of GE equipment must only utilize qualified personnel to perform electrical servicing on the equipment.
NOTE: All relevant preliminary network port installations at the prepared site must be performed by authorized contractors. The purchaser of GE equipment must utilize only qualified personnel to perform servicing of the equipment. 2-3-3 Site Recommendations The following are (optional) site recommendations.
Recommended Ultrasound Room Layout Figure 2-1 below shows a floor plan illustrating the recommended layout of the Ultrasound Room and depicting the minimal room layout requirements. Dedicated Power Outlets LOGIQ S8 Hospital Network Cabinet for Software and Manuals (optional) 35.5 IN.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 2-3-4 Networking Setup Requirements 2-3-4-1 Stand-alone Unit (without Network Connection) None 2-3-4-2 Unit Connected to Hospital’s Network Supported networks: • Ethernet 2-3-4-3 Purpose of the DICOM Network Function DICOM (Digital Imaging and Communications in Medicine) services provide the operator with clinically useful features for moving images and patient information over a hospital network.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 3 Setup Instructions Section 3-1 Overview 3-1-1 The Purpose of Chapter 3 This chapter contains information needed to setup the LOGIQ™ S8 ultrasound system. Included are procedures to receive, unpack and configure the equipment.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-2-2 Installation Warnings 1.) Since the LOGIQ™ S8 weighs approximately 90 kg (200 lbs.) without peripherals, two people are required to unpack it.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-2-2-4 Brake Pedal Operation REMEMBER: If the front wheel brakes are engaged for transportation, release brake WARNING WARNING pedals (brakes on front wheels under the foot rest) to disengage the lock.
Unpack the devices such a way that packaging can be reused. For warranty purposes, storage of the above is required for one year from date of purchase. If the shipping crate is damaged, please inform the GE Healthcare sales representative immediately. NOTICE...
Page 63
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-3 Receiving and Unpacking the Equipment (cont’d) The envelope with delivery address, packing list and invoice is located on the front panel of the crate.
Page 64
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 3-5 Unpacking Procedure Step Task Remove the option box on front of the system.. option box on front of the system Remove the monitor pads from the both sides of the monitor and remove the 4 pads of the box bottom assy..
Page 65
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 3-5 Unpacking Procedure Step Task Unlock the casters and place the 4 caster's derection like the picture below and then using the incline plane of the box bottom assy, slowly move the system from the box.
Check the power cord for cuts, loose hardware, tire marks, exposed insulation, or any deterioration. Power Cord Verify continuity. Replace the power cord, as required. NOTE: Report any items that are missing, back-ordered, or damaged, to your GE Healthcare sales representative. The contact address is shown in Contact Information on page 1-14.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-4-2 EMI Protection This unit has been designed to minimize the effects of Electo-Magnetic Interference (EMI). Many of the covers, shields, and screws are provided primarily to protect the system from image artifacts caused by this interference.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-5 Connection of Auxiliary Devices NOTE: Normally auxiliary devices and peripherals come pre-installed with the system. Table 3-7 below outlines hardware installation procedures described in the sub-sections.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-2 Connecting the Black & White Printer 1.) Power OFF/Shutdown the system as described in: Section 3-6-3 on page 3-24. 2.) Connect the Black & White printer according to correct connection scheme as described in...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-3 Connecting the Color Printer 1.) Power OFF/Shutdown the system as described in: Section 3-6-3 on page 3-24. 2.) Connect the Color printer according to correct connection scheme as described in...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-4 Connecting the Secondary “Patient” LCD Monitor Secondary LCD “Patient” Monitor MUST NEVER be connected to the LOGIQ™ S8 ultrasound CAUTION systems mains supply directly!
Page 75
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-4 Connecting the Secondary “Patient” LCD Monitor (cont’d) appropriate Transformer Secondary Monitor HDMI to DVI / HDMI to HDMI cable connected to the...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-5 Connecting the Footswitch The footswitch should be directly connected to any accessible USB-port on the LOGIQ™ S8 (e.g., on rear of the system).
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-6 Connecting the USB Flash Memory Stick Before connecting an USB device, please read General Remarks and Hints when using external USB- NOTICE Devices on page 3-20.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-5-8 General Remarks and Hints when using external USB-Devices Do not connect or disconnect any external USB-devices to or from the system while...
The connection of the LOGIQ™ S8 ultrasound unit to a power source should be performed by a qualified person who has completed basic LOGIQ™ S8 System User Training. Use only the power cords, cables and plugs provided by or designated by GE Healthcare to connect the unit to the power source.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-6-2-2 Back End Processor Boot Up When AC power is applied to the scanner, the ON/OFF button on the control panel illuminates green, NOTICE indicating that the System (including the Back-end Processor) is in Standby mode.
Figure 3-12 GE Healthcare wallpaper with progress bar NOTE: Startup GE Healthcare wallpaper with progress bar may differ depending on product type and release. 5.) The software initiates and sets up the Front-End electronics and the rest of the scanner (incl.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-6-3 Power Off / Shutdown After turning off a system, wait at least 10 seconds before turning it on again. NOTICE The system may not be able to boot if power is recycled too quickly.
Page 83
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 6.) Press on the brakes to block the front caster wheels. 7.) Disconnect probes. (Turn the probe locking handle counterclockwise and then pull the connector straight out of the probe port.)
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-6-4 Transducer Connection 3-6-4-1 Connecting the Probe Inspect the probe before and after each use for damage or degradation to the housing, strain CAUTION relief, lens, seal, cable and connector.
When deactivating the probe, the probe is automatically placed in standby mode. To deactivate a probe: 1.) Ensure the LOGIQ S8 is in freeze mode. If necessary, press the Freeze key. 2.) Gently wipe the excess gel from the face of the probe.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-7 Printer Installation NOTE: For Connection schemes refer to Section 3-5 "Connection of Auxiliary Devices" on page 3-10. For further installation instructions see: •...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-7-3 Adding Printer to the system 1.) Select Utility -> Connectivity -> Service. 2.) Add the Standard Print. 3.) Highlight Standard Print in the Service list.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-7-4-2 UP-D25MD - Printer Settings 1.) Call up the ‘Printer Preferences’; operation see: Section 3-7-4 "Adjustment of Printer Settings" Settings for Paper Size MUST match with the used Paper (large/small) and also the right color ink NOTICE cartridge has to be used.
Page 90
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-7-4-2 UP-D25MD - Printer Settings (cont’d) 3.) Select the page. From the “Color Adjust” pop-up menu select: GRAPHICS a.) Color Balance: Cyan = 0; Magenta = 0; Yellow = 0 b.) Gamma Select: Gamma 1...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-7-5 Setting Printer to Print Reports 3-7-5-1 Setting up the Printer to Print Reports To set up the Off-Line Printer to print reports, 1.) Press Utility ->...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-8 System Configuration 3-8-1 System/General Preset Menu The System/General screen allows you to specify hospital name and system date and time. Figure 3-21 System/General Preset Menu...
Page 93
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 3-10 General User Interface Preset Parameter Description Color Level (restart needed) Select System Color according to the condition of the room. Table 3-11...
Page 94
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 3-15 Scan Assistant Preset Parameter Description Auto Selection Off, Category, or Description. • Off. The Scan Assistant selection on the Patient screen is completely manual. It will say “None”...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-11 Connectivity Setup The LOGIQ™ S8 (sp) ultrasound system can be connected to various connectivity devices. The following sections describe how to connect the system to a remote archive/work station or a DICOM service, using a TCP/IP connection.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-11-1-2 Dataflow Examples The local database is used for patient archiving. Images are stored to internal hard drive. The local database is used for patient archiving.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3-11-1-3 Stand-alone LOGIQ™ S8 If digital images or 3D/4D data sets (if available) are stored, they should be saved in the Archive (Image Management System software).
This greatly improves query capability. DICOM Structured Reporting creates coded clinical data that can be used for clinical research, outcomes analysis, and disease management. DICOM Structured Reporting is a standardized format for medical results. LOGIQ S8 supports the following templates: •...
3.) Select Save settings. 4.) Re-boot the ultrasound system. NOTE: TCPIP settings do not get restored when restoring backups. This is per system design. The LOGIQ S8 IP address MUST BE unique. Figure 3-25 Connectivity TCPIP Preset Menu Table 3-21...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 3-22 IP settings Preset Parameter Description DO NOT select this box to enable dynamic IP Address selection. Enable DHCP NOTE: The system shall disable IP-Address, Subnet Mask, and Default Gateway when the user chooses to use DHCP.
Properties: IP Address Type the device's IP address. Properties: AE Title AE Title of the LOGIQ S8. NOTE: Only available for MyComputer. Properties: Port Number IP Port Number Used for DICOM, set by default to 104. NOTE: Only available for MyComputer.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Service Parameters - lists parameters for the service currently selected in the Services section. The name and parameters in this section change, depending on what service is currently selected. In the above figure, this section shows DICOM Print parameters.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-13 Connectivity Setup Worksheet Site System Information Comments: Floor: Site: Dept: Room: LOGIQ™ S8 Type: REV: CONTACT INFORMATION Name Title E-Mail Address...
Page 108
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 3-13 Connectivity Setup Worksheet (cont’d) LOGIQ™ S8 IP Address Local Port Host Name AE Title Net Mask ROUTING INFORMATION GATEWAY IP Addresses...
Check that the correct User Manual(s) for the system and software revision, is included with the installation. Specific language versions of the User Manual may also be available. Check with your GE Sales Representative for availability. Chapter 3 - Setup Instructions...
Page 110
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL This page was intentionally left blank. 3-52 Section 3-14 - Paperwork...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 4 Functional Checks Section 4-1 Overview 4-1-1 Purpose of Chapter 4 This chapter provides procedures for quickly checking major functions of the LOGIQ™ S8 scanner diagnostics by using the built-in service software, and power supply adjustments.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 4-3 General Procedure SYSTEM REQUIRES ALL COVERS CAUTION Operate this unit only when all board covers and frame panels are securely in place.
Page 113
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Location Main LCD LCD Arm Control Panel (OPIO) Rear Handle Top Cover Front Cover Side Covers Base Casters Rear Cover External I/O Panel - AC Power Plug Holder 1.) Check for no loose or cracked parts on above locations.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-2 Mechanical Parts Functional Check Pay attention to moving parts and pinch point when performing mechanical parts functional CAUTION check. !! CAUTION: Figure 4-3 System Mechanical Checkpoint...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-2-4 Swivel/Brake Lock Caster System weighs approximately 100kg. Pay attention for system stability when working with CAUTION the casters !! CAUTION: NOTE: This procedure applies to RIGHT REAR Caster only.
Page 120
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-2-5 Swivel/Brake Lock Caster System weighs approximately 100kg. Pay attention for system stability when working with CAUTION the casters. !! CAUTION: NOTE: This procedure applies to casters other than RIGHT REAR Caster.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-3 Power On/Off After turning off a system, wait at least 10 seconds before turning it on again. NOTICE The system may not be able to boot if power is recycled too quickly.
Page 122
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL OFF(Stand-by) Figure 4-11 On/Off Button on Control Panel and indicator color 6.) Verify On/Off button color changes to GREEN. 7.) Verify on-board peripherals power is also turned ON.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-3-2 Sleep Mode Check NOTE: This procedure assumes systems is already up and running. 1.) Press the ON/OFF button (see: Figure 4-11) on the control panel. Following dialog appears.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-3-3 Power Off / Shutdown Check After turning off a system, wait at least 10 seconds before turning it on again. The system may not be NOTICE able to boot if power is recycled too quickly.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-4 System Information 4-3-4-1 Software Version 1.) From the touch panel, select Utility -> System -> About. 2.) Note “Software Version” in Software Group.
ANUAL 4-3-4-2 Service Platform Confirmation 1.) From the touch panel, select Utility -> Service. 2.) On Service Browser, select GE Service, and enter the password. 3.) Note “SvcPform” version. Figure 4-15 Software Platform version Chapter 4 - Functional Checks 4-16...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-4-3 USB Port Test Required Equipment : Service Dongle External Port Test 1.) Plug service dongle to the following locations. Refer to Section 3-8-2 for locations.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-5 System Integration Checks 4-3-5-1 OPIO Test TGC Knob AN Keyboard B Button Freeze Key Figure 4-17 OPIO 1.) Power ON the system.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL comment Figure 4-19 6.) Connect any probe. (if not connected) 7.) Go to Live CF Mode. (Press “CF” Mode button, unfreeze.) 8.) Verify both B button and CF button are lit GREEN.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-6 Peripheral Checks 4-3-6-1 DVR Test (if equipped) Required: Blank [DVD+RW] media. 1.) Make sure the tab menu of “Video” is found on the right-most touch panel tab. If not found, go to “Utility”...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-6-7 Gel Warmer Test 1.) Insert Gel Bottle into Gel Warmer. 2.) Power ON the warmer. 3.) Verify Gel gets warm. NOTE: Depending on environment, Gel requres 30 minute or more to warm up.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Verify no vertical “streaks” of color that significantly contrasts the surrounding color. Figure 4-21 Color Flow-Mode 4-3-7-4 Pulse Doppler Mode Figure 4-22 1.) From Utility ->...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-7-6 M-Mode 1.) Press B Mode Button. 2.) Press M Mode Button. 3.) Verify that system scan B/M with the activated probe. Figure 4-25 M-Mode...
Page 135
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Verify BF Mode. Figure 4-27 B-Flow Mode 5.) From the touch panel, select “COLOR” 6.) Verify B-Flow Color is shown. Figure 4-28 B-Flow Color Mode...
Page 136
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4-3-8 OPIO Interface Check 1.) Exit to Windows Desktop (Refer to Section 5-9-1 Exiting to Windows Desktop). Figure 4-29 Windows Desktop 2.) Double Click on icon “OPIO_Test.exe”.
Page 137
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5.) Verify OP Panel button operation is reflected on diag window. Figure 4-31 OP Panel button screen on diag window NOTE: In above example, key “Alt” is pressed.
Page 138
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 4-4 Board Diagnostics GFS- Jig youhi CW Bd BF192 EEPROM GFS Swept Demodulator Test GFS Front-End Interface Test GFS Analog Test GFS Memory Access Test...
Page 139
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL GFS- Jig youhi CW Bd BF192 EEPROM PC Interactive AVI Playback CD-R Test optonal optonal DVD-R DVD+RW Keyboard Microphone Monitor optonal Trackball Sound...
Page 140
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL This page was intentionally left blank. Chapter 4 - Functional Checks 4-30...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 5-2 General Information LOGIQ™ S8 is a digital beamforming curved-, linear- and phased array ultrasound imaging system. The system supports various operating mode such as •...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5-2-3 System Options Option Probe Holder Cabinet for BW Printer, Color Printer, VNAV Unit Single CW Connector Side Tray Figure 5-4 System Options...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5-2-4 System Ports USB Ports Rear Panel Figure 5-5 System Ports System is equipped with two USB ports in front. One is customer use and connected to USB controller direct.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 5-4 Software Options 5-4-1 Options Following options are offered for LOGIQ™ S8. Table 5-2 Software Options Software Options Description Advanced 3D Designed for rendering B Mode and Color Flow Mode images, e.g., vessel trees.
LOGIQ™ S8 Norwegian/Danish Keyboard LOGIQ™ S8 Russian Keyboard LOGIQ™ S8 Swedish Keyboard 5-6-2 Peripheral Options Following options are offered for LOGIQ S8. Table 5-5 Peripheral Option Printers LS8 Sony UP-897MD Digital B/W Printer Kit LS8 Sony UP-D25 Digital Color A6 Printer Kit...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5-7-4 Air Flow Distribution Through the filter grid on the front of the system, air flow into the LOGIQ™ S8 scanner. By means of the 1 FAN, air is blown through the nest-box, and the warm air exits the scanner through holes in the left side panel and rear of the system.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 6 Service Adjustments Section 6-1 Overview 6-1-1 Purpose of Chapter 6 This chapter describes how to test and adjust the mechanical capabilities of a scanner that may be out of specification.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 6-3 LCD Monitor Adjustment The LOGIQ™ S8 has a free adjustable LCD monitor in relation to the user interface. The digital control panel is located at the front of the color monitor. It is NOT recommended to change the pre-adjusted settings.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 6-2 Setting for Main Menu Sub Menu Range LOGIQ™ S8 English/German/ French/Spanish/ Italian/Swedish/ Language Chinese/Japanese English H-Position 0~100% V-Position 0~100% Half Tone...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL (Default : 80) Figure 6-3 Contrast Adjust NOTE: Brightness and Contrast should be adjusted at examination room light conditions. 6-3-1-2-1 Gamma 1.) Press the MENU (middle) key of the monitor controls over 10 sec.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 6-3-2 Function Figure 6-4 Function 6-3-2-1 Scale 1.) Press the MENU (middle) key of the monitor controls over 10 sec. 2.) Select the FUNCTION -> Scale by pressing the < LEFT or RIGHT > button to move the cursor and the MENU (middle) key.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Figure 6-5 Information 6-3-2-3 Memory Recall 1.) Press the MENU (middle) key of the monitor controls over 10 sec. 2.) Select the FUNCTION -> MEMORY RECALL by pressing the < LEFT or RIGHT > button to move the cursor and the MENU (middle) key.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 6-3-3 Figure 6-6 OSD 6-3-3-1 Language 1.) Press the MENU (middle) key of the monitor controls over 10 sec. 2.) Select the OSD -> LANGUAGE by pressing the < LEFT or RIGHT > button to move the cursor and the MENU (middle) key.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Adjust the HALF TONE by pressing the < LEFT or RIGHT > button to decrease/increase the value.(default : 50) 6-3-4 Exit When finishing the Adjusting Menu, select the EXIT (middle) and press the MENU (middle) key.
Remote Access to Service Platform 7-5-1 General 7-5-2 How the Customer enables/disables Disruptive Mode and VCO 7-5-3 GE Icon and Remote Connection 7-5-4 Customer Granting Full Remote Access Permission to GE Service Technician Minimum Configuration to Boot/Scan Chapter 7 - Diagnostics/Troubleshooting...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 7-2 Collect Vital System Information 7-2-1 Collecting System Information 1.) From the touch panel, select Utility -> System-> About. 2.) Record software version and System Image version...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 7-3 Check Points Voltages 7-3-1 Visual check 7-3-1-1 Common Power Supply (CPS) Turn on mains switch and check green LED inside Power.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 7-3-2 LED for Power Status LEDs near the front cooling fan can provide information pertaining to the DC power distribution status. 1.) Remove Front Cover (no tools required)
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 7-4 Screen Captures and Logs There may be times when the customer or field engineer will want to capture a presentation on the screen so it may be recovered by the OnLine Center.
If the console is setup to connect to InSite ExC server (refer to Chapter.3 for InSite ExC Configuration), then remote access technology may provide GE technicians the possibility to view the entire customer’s desktop and operation system for diagnostics and trouble shooting.
Customer Granting Full Remote Access Permission to GE Service Technician 7-5-4-1 If GE Service Technician requests Remote Access Permission If a GE Service technician requests remote access to your LOGIQ™ S8 scanner, following “InSite Notification” appears on the systems s creen. select [Yes] to enable “Disruptive Mode”...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 8 Replacement Procedures Section 8-1 Overview 8-1-1 Purpose of Chapter 8 This chapter contains replacement procedures for different modules and their subsystems.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 8-1 Chapter 8 Contents Section Description Page Number 8-15 8-42 Replacement around ACQ Box 8-16 8-55 Replacement of CSI and Fan 8-17...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-2 System Software - Installation/Upgrade Procedure 8-2-1 Introduction This section describes procedure to install/upgrade software to system. 8-2-2 Manpower One person ~ 1 hour (depends on contents of System DVD, peripherals, etc.)
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8.) A confirmation window appnears, and then hit the Enter key. 9.) Approx. 20 minutes later, loading the software will be completed. 10.)A message appears, and then presses CTRL-ALT-DEL to reboot the system.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5.) Select “G” drive in the tree view. 6.) Double click “LoadSoftware.bat”. Software Installation will begin. 8-2-5-3 Application Software Installation 7.) Application Software Installation process will take approximately 10 minutes NOTE: The following message box will appear, but can be ignored.
Page 174
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8.) After the installation completes, the system will be rebooted automatically. NOTE: Do not remove Application Software DVD from drive. 9.) About 1 minute later, the following message box will appear. Click “OK” button.
Page 175
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10.)If SW License window appears, then enter correct Option String and click “OK”. Chapter 8 - Replacement Procedures...
For the sake of simplicity, we have used the CD-R in the examples in this section. 8-4-1-2 General Notes NOTE: When you restore backup data from the Utility menu, the LOGIQ S8 application usually restarts automatically when the restoring is complete. NOTE: To perform backup and restore procedures, you must login with administrator privileges.
5.) In the Media field, select the appropriate Source device. 6.) Select Restore. The system performs the restore. As it proceeds, status information is displayed on the Backup/ Restore screen. 7.) The LOGIQ S8 restarts automatically when Restore is done. Chapter 8 - Replacement Procedures...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-4-4 EZBackup and EZMove EZBackup or EZMove allows you to manage hard disk space (move images off the hard drive) while maintaining the patient database on the scanner, as well as to back up the patient database and images.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-4-5 Option Keys 1.) From the touch panel, select Utility -> System-> Backup/Restore. 2.) ADD or REMOVE new option key at “Enter New Option Key” field.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-5-4 Installation Procedure 1.) Front cover to be installed in reverse order of removal. 2.) Align the edges and simply push to make sure all three “latches” are engaged.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-6 Replacement Top Cover 8-6-1 Manpower 1 person, 5 min. 8-6-2 Tools None required. 8-6-3 Removal Procedure 1.) Top Cover shapes differ for each configuration, but removal/installation procedure are the same.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-6-4 Installation Procedure 1.) Cover to be installed in reverse order of removal. 2.) Make sure “latches” on both sides are engaged. NOTE: For Mid and High Cabinet type, there is “Guide Rail”...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-7 Replacement Side Cover 8-7-1 Manpower 1 person, 15 min. 8-7-2 Tools Phillips Driver. 8-7-3 Removal Procedure 8-7-3-1 Removal Procedure - Side Cover (L)
Page 185
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Pull out Side Cover (L). There is mechanical hook on bottom of the part. Figure 8-10 Pull out Side Cover(L) Chapter 8 - Replacement Procedures...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-7-3-2 Removal Procedure - Side Cover (R) Side Cover (L) Side Cover (R) Figure 8-11 Side Cover (R) 1.) Remove Top Cover. 2.) Remove three screws for Side Cover (R).
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-7-4 Installation Procedure 1.) Cover to be installed in reverse order of removal. 8-7-5 Functional Check Visual inspection only. Test Refer to Note...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-11 Replacement of Monitor and LCD Arm Plastic Covers 8-11-1 Manpower Two person, 15 minutes. 8-11-2 Tools Phillips screwdriver, Wrench. 8-11-3 Preparations 1.) Lock the Monitor Arm to prevent hazard.
Page 192
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 2.) Unscrew Monitor Cable Holder Bracket. Figure 8-20 3.) Unscrew the Cap-tire screw to disconnect the Monitor cable. Refer to the figure below.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Unscrew 2 screws, then separate the Monitor from the Monitor Stand Arm. Refer to the figure below. Figure 8-22 Unscrewing 2 screws & separating the Monitor...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-11-6 Functional Check Test Refer to Note System Exterior Visual Check Section 4-3-1 Visual check Main LCD Mechanical Parts Functional Check Section 4-3-2...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-12 Replacement of OPIO and Related Parts NOTE: This section describes removal and installation of OPIO and related parts. OP Panel Assy itself, Main OPIO PWA Assy, OP LCD Touch Panel Assy, Full A/N Keyboard, TGC...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-12-3-1 Removal Procedure - Trackball Ring NOTE: Removal of Trackball Ring and Cleaning does not require tools. 1.) Turn the ring counter clock-wise 2.) Lift trackball from OP Panel...
Page 197
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 1.) Remove 5 screws from bottom of the OPIO Base (M4x25mm). Figure 8-27 Bottom of OPIO Base 2.) Remove 2 screws from rear of the OPIO Base (M4x8mm).
Page 198
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Use “Hold Bar” to keep OP Panel in place as shown below. Hold Bar Figure 8-29 Hold Bar 8-30 Section 8-12 - Replacement of OPIO and Related Parts...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5.) Remove two cables from location [A]. 6.) Remove a connector from location [B]. 7.) Remove two connectors from location [C]. Figure 8-30 Removal of cable & connectors...
2.) Remove 4 screws around trackball. 3.) Slowly lift up trackball from OP Panel. Figure 8-32 Trackball NOTE: LOGIQ S8 Trackball Cable length is 80mm. 210mm cable is for Voluson S8 and not to be used for LOGIQ S8. 8-12-3-5 Removal Procedure - TGC Assy 1.) Remove TGC Knobs.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-12-3-9 Removal Procedure - Joystick and Encoder on PWA 1.) Remove OP Panel Main PWA Assy. 2.) Remove “Rubber Sheet” on reverse side of PWA Assy.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-12-4 Installation Procedure 1.) Parts to be installed in reverse order of removal. Note: Make sure to assemble “Rubber Sheet” securely to PWA...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-13 Replacement of the Caps for Hardkeys 8-13-1 Manpower One person, approx. 1 minute/cap. 8-13-2 Tools Small-sized slotted screwdriver or tweezers. 8-13-3 Removal Procedure 1.) By means of a small slotted screwdriver, carefully push against the hardkey cap.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-13-4 Installation Procedure 1.) Parts to be installed in reverse order of removal. 8-13-5 Functional Check Test Refer to Note System Exterior Visual Check...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 2.) Loosen the two screws behind of removed “1” and “ENTER” key. Figure 8-43 3.) Insert Tool B and lift the A/N key base from OPIO frame.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Assemble AN Keyboard part in reverse order of removal. 4.) Push “Shading” material along edge of AN Keyboard using AN Key tool A.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-15 Replacement around ACQ Box NOTE: This section covers replacement of components related to ACQ Box - PID assy, BF192 Assy, GFS...
Page 211
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Disconnect Cables. Figure 8-49 Disconnecting Cables (Signals) Description Note To main LCD OPIO To OPIO power and signal USB 2.0 For Color/BW Printers, VNAV...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-15-4 Removal Procedure - PID, BF192, GFS, CPS NOTE: Before working with ACQ box, be sure to remove probes. 1.) Get ACQ Box access.
Page 213
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL BF192, PID Inner shape of CPS Figure 8-52 Pulling out the board Assy Chapter 8 - Replacement Procedures 8-45...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-15-4-1 Removal Procedure - Separating PID and BF192 1.) Unscrew 5 (five) screws and separate PID Assy from the BF192. Figure 8-53 Separating PID Assy from the BF192 NOTE: Stacking Connector is designed to always remain on PID side.
Page 215
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-15-4-2 Removal Procedure - Separating PID and BF192 NOTE: Except for very early production models, BF192 is fitted with air flow louver. In such case, apply the following procedures...
Page 216
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Remove 4 (four) screws around BF192 Top view 4.) Separate BF192 with PID NOTE: Stacking connector is designed to always remain on PID side...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL NOTE: Inserting EEPROM in wrong direction will result in permanent damage to EEPROM or to GFS board. Proceed with caution. 6.) Verify tips of all 8 pins are aligned with U32 socket.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-15-5 Installation Procedure 8-15-5-1 Installation Procedure - PID, BF192, GFS, CPS 1.) Parts to be installed in reverse order of removal. NOTE: Cables are designed to be routed as follows...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-15-7 Removal Procedure - ACQ Box 1.) Remove Front Cover. 2.) Remove 2 screws. Refer to the figure below. Figure 8-61 Removing the front cover 3.) Get access to ACQ Box (Refer to Section 8-18-3 ACQ Box Access).
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-16 Replacement of CSI and Fan 8-16-1 Manpower One Person, 10 minutes. 8-16-2 Tools Standard Phillips Screwdriver. 8-16-3 Removal Procedure 1.) Remove Front Cover.
Page 224
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Unscrew four screws to separate CSI Assy Figure 8-66 Removing the CSI Assy 5.) Remove 4 screws from Indicator Bracket. Figure 8-67 Fan Bracket...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 6.) Unscrew four screws to separate FAN Assy. Figure 8-68 Removing the FAN Assy 8-16-4 Installation Procedure 1.) Parts to be installed in reverse order of removal.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 2.) Remove Nut Figure 8-72 Removable Nut of Caster Proceed with extreme caution and avoid system tipping over. The system weighs approximately CAUTION 100kg.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-19 Replacement of the SOM,HDD and DVR 8-19-1 Manpower One person, 5 minutes. 8-19-2 Tools Phillips screwdriver. 8-19-3 Removal Procedure 1.) Unscrew eight screws and separate Hard disk from the GFS.
Page 230
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 2.) Remove the bracket from the hard disk. Figure 8-74 Removing the hard disk bracket 3.) Unscrew five screws to separate SOM board from the GFS.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Figure 8-77 Push the SOM in both side of GFS Assy 5.) Unscrew four screws to separate DVR from the GFS.. Figure 8-78 Drawing up the DVR...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-19-5 Note on EEPROM Replacement NOTE: EEPROM on GFS contains VPD (Vital Product Data) for SOM (ComExpress). This VPD contains information such as system serial number to be matched to Software License Key, or Board revision number that is cross referenced to system software for compatibility.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-19-5-1 Accessing EEPROM 1.) Exit to Desktop (Refer to Section 5-11 for details). 2.) Start VPD Editor by clicking icon on the desktop “vpdedit”.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Note : If following windows pop up without changing any parameters (i.e. simply browsing through the VPD contents), then press “NO” before continuing.
Page 235
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Click “OPEN” to load selected file. NOTE: This procedure can be applied to other components with VPD, for example, for initializing PID VPD.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-19-5-3 Modifying contents of EEPROM (ComExpress VPD) System reads off Console Serial Number from EEPROM and match that against installed option string. Therefore, without having correct serial number in EEPROM (ComExpress VPD).
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-20-5 Removal Procedure (Monitor Cable and OPIO Cable) 6.) Unscrew 1 screw to remove F-Block Bottom Cover. 7.) Gently push connector through center of OPIO base.
Page 240
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 9.) Remove Cable duct and Remove cable cramp. Figure 8-89 10.)Loosen Ground Cables. Figure 8-90 11.)Loosen Ground Cables. 12.)Remove the flexible cover and unscrew 2 Cap Screws..
Page 241
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 13.)Unscrew five screws to separate back panel and disconnect Main power cable. Figure 8-92 Disconnecting the Main power cable 14.)Unscrew three screws to remove Cable Cover Bracket. Refer to the figure below.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 15.)Disconnect Harness cables. Figure 8-94 Disconnecting Harness cables 8-20-6 Installation Procedure Install components in reverse order of removal. 8-20-7 Functional Check Power ON and Visual check on LCD monitor to see if image displays without color distortion.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-21 Replacement of Peripheral Cable Assy 8-21-1 DVD Cables 8-21-1-1 Manpower 8-21-1-2 Tools 8-21-1-3 Removal Procedure 1.) Remove the DVD cable connector from the rear panel.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Pull up the DVD cables from the gap. Figure 8-97 Pull up DVD cables 4.) Remove the DVD cable connectors from the DVD drive.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-21-2 B/W and Color Printer Cables 8-21-2-1 Manpower 8-21-2-2 Tools 8-21-2-3 Removal Procedure 1.) Remove the printer USB cable connector from the rear panel.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Remove the printer USB and power cable connectors from the printer. Figure 8-101 Remove printer USB and power cable connectors from printer...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Remove the VNAV Option USB and power cable connectors from the VNAV. Figure 8-104 Remove VNAVI Optioin USB and power cable connectors from VNAV...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-22 Replacement of the Probe Holder(Kit), Cable Hook, and Extended probe holder Replacement of Circle Key Caps only 8-22-1 Manpower 1 person, 5 minutes.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-22-3-3 Removal Procedure - Extended Probe Holder 1.) Remove two screws from Cable Hook as shown below Figure 8-109 Probe Holder 8-22-4 Installation Procedure 1.) Parts to be installed in reverse order of removal.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Remove cables from printer. 4.) Unscrew four screws and pull put the B/W printer. Figure 8-113 Removal Color printer BRKT 8-24-1-1-4 Installation Procedure 1.) Parts to be installed in reverse order on removal.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-24-1-2 B/W on Side Cabinet 8-24-1-2-1 Manpower 1 person, 1 hour 8-24-1-2-2 Tools Philips screwdriver 8-24-1-2-3 Removal Procedure 1.) Remove the B/W printer cables from the system (Refer to section X-X-X).
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-24-1-2-4 Installation Procedure 1.) Parts to be installed in reverse order on removal. 8-24-1-2-5 Functional Check Test 1: Print an image by pressing the button P1 on the operator panel. (P1 key should be configured correctly) Verify1: - Verify that image can be printed.
Page 257
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Remove the Color printer cables. (refer to Section 3-5-3) 4.) Unscrew four screws and pull put the Color pritner Figure 8-118 Removal Color printer BRKT...
Page 258
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-24-2-2 Color printer on High Console 8-24-2-2-1 Manpower 1 person, 1 hour 8-24-2-2-2 Tools Philips screwdriver 8-24-2-2-3 Removal Procedure 1.) Pull out the dummy case Mid B/W polaris.
Page 259
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 4.) Unscrew four screws and pull put the Color pritner Figure 8-121 Removal Color printer BRKT 8-24-2-2-4 Installation Procedure 1.) Parts to be installed in reverse order on removal.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Unscrew four screws and pull put the VNAV baybird box Figure 8-124 Removal VNAV 8-24-3-1-4 Installation Procedure 1.) Parts to be installed in reverse order on removal.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-25 Replacement of the Speaker 8-25-1 Man Power 1 person, 10 minutes. 8-25-2 Tools Phillips Screwdriver. 8-25-3 Removal 1.) Remove Rear Cover.
Page 264
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 7.) Remove 1 screw holding Ground Wire (Green Wire). 8.) Remove 8 screws holding Speaker Figure 8-128 Removal screws of Speaker 8-25-4 Installation 1.) Parts to be installed in reverse order of removal.
Page 265
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 8-26 Replacement of the Monitor Arm NOTE: Some of the photos resembles consoles other than LOGIQ™ S8, but Monitor Arm is common part as Polaris Platform and therefore, service procedure is the same.
Page 266
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Remove 2 cable ties. Refer to the figure below. Figure 8-131 Removing the cable ties 4.) Unscrew 1 screw and remove the 1st arm cover polaris. Refer to the figure below.
Page 267
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 5.) Extract the Monitor cable through the hole. Refer to the figure below. Figure 8-133 Pulling out Harness cable 6.) Unscrew one screw to extract the setscrew. Refer to the figure below.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Unscrew four screws and pull put the Drawer. Figure 8-138 Removal Drawer 8-29-1-4 Installation Procedure 1.) Parts to be installed in reverse order on removal.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 8-29-2 Drawer on High Cabinet 8-29-2-1 Manpower 1 person, 30 minutes 8-29-2-2 Tools Philips screwdriver 8-29-2-3 Removal Procedure. Figure 8-139 Remove dummy case 2.) Draw the cabinet out of the frame Assy.
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 3.) Unscrew four screws and pull put the Drawer. Figure 8-141 Removal Drawer 8-29-2-4 Installation Procedure 1.) Parts to be installed in reverse order on removal.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 9 Renewal Parts Section 9-1 Overview 9-1-1 Purpose of Chapter 9 This chapter gives an overview of replacement parts available for the LOGIQ™ S8..
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 9-2 List of Abbreviations Alternating Current Analog to Digital Converter A/N Key Alpha Numeric Keys ASIC Application Specific Integrated Circuit Assy Assembly...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 9-3 Parts List Groups Figure 9-1 Console Views Table 9-2 Mechanical and user accessible parts Item Part Group Name Table Number Description...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 9-5 LCD Monitor Figure 9-3 LCD Monitor Table 9-4 User Interface Item Part Name Part Number Description 5392293 Full 19" monitor set with hinge 19"...
Page 283
EEPROM on GFS Board. This part have blank VPD and needs 5418291 EEPROM reprogramming before use. Below 2 FRUs are not indicated Item Part Name Part Number Description LOGIQ S8 R1.0.X 6020801 Application Software DVD 5418145 LS8 Pencil CW HW Kit Chapter 9 - Renewal Parts 9-11...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 9-8 Mechanical Parts Figure 9-7 Mechanical Parts 9-12 Section 9-8 - Mechanical Parts...
Page 285
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 9-7 Mechanical Parts Item Part Name Part Number Description 5400391 except swivel lock caster (3 per console) Total Lock Caster 5400392 Rear-Right caster (1 per console)
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 9-9 Options Figure 9-8 9-14 Section 9-9 - Options...
Page 287
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 9-8 Options Item Part Name Part Number Description 5172178 Probe Holder Extention Optional Probe Holder 5380960 3 button switchs operated by the feet...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 9-11 Power Cord Figure 9-10 Power Cord Chapter 9 - Renewal Parts 9-17...
Page 290
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 9-10 Power Cord Item Part Name Part Number Description Power Cord for 5182611 Power Cord for India India Power Cord for 5182235...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Chapter 10 Care & Maintenance Section 10-1 Overview 10-1-1 Periodic Maintenance Inspections It has been determined by engineering that your LOGIQ™ S8 system does not have any high wear components that fail with use, therefore no Periodic Maintenance Inspections are mandatory.
Testing results, corrective action and the effects of corrective action must be documented and maintained on the site. Your GE service representative can help you with establishing, performing and maintaining records for a quality assurance program. Please contact us for coverage information and/or price for service.
Page 293
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-3-1 How often should care & maintenance tasks be performed? (cont’d) Table 10-2 Customer Care Schedule Item Service at Indicated Time Notes •...
Page 294
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 10-2 Customer Care Schedule Item Service at Indicated Time Notes Also after corrective Surface Probe Leakage • maintenance or as required by Current Checks your facilities QA program.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 10-4 Tools Required 10-4-1 Special Tools, Supplies and Equipment 10-4-1-1 Specific Requirements for Care & Maintenance Table 10-3 Overview of Requirements for Care & Maintenance...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 10-5 System Maintenance 10-5-1 Preliminary Checks The preliminary checks take about 15 minutes to perform. Refer to the system user documentation whenever necessary.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-5-2 Functional Checks The functional checks take about 60 minutes to perform. Refer to the LOGIQ™ S8 Basic User Manual whenever necessary. 10-5-2-1...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-5-2-2 Peripheral/Option Checks If any peripherals or options are not part of the system configuration, the check can be omitted. Refer to Table 3-8, “Approved Peripherals,” on page 3-45 for a list of approved peripherals.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-5-5 Physical Inspection Table 10-9 Physical Checks Step Item Description Labeling Verify that all system labeling is present and in readable condition. Scratches & Dents Inspect the console for dents, scratches or cracks.
The Basic User Manual and/or care card provides a complete description of probe care, maintenance, cleaning and disinfection. Ensure that you are completely familiar with the proper care of GE probes. Ultrasound probes can be easily damaged by improper handling. Review the Basic User Manual of LOGIQ™...
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Section 10-6 Using a Phantom Refer to the User Manual of the Phantom for information on using a phantom and quality assurance tests. For measurement accuracy of the system review chapter 13.5 of the Basic User Manual of LOGIQ™...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-7-2 GEHC Leakage Current Limits The following limits are summarized for UL60601-1 (For USA), IEC 60601-1 Medical Equipment Safety Standards and IEC 62353 Medical Electrical Equipment - Recurrent test and test after repair of medical electrical equipment.
Page 303
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL Table 10-14 Type BF Patient Auxiliary Limits Country Conditions Others Close Protective earth and close neutral with normal polarity 0.1mA* 0.1mA*** Close Protective earth and close neutral with reverse polarity 0.1mA*...
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-7-3 Earth Leakage Current Test 10-7-3-1 Definition This test measures the current that would flow to a grounded person who touched accessible protectively-earthed parts of equipment if the ground wire should break.
GE H DRAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-7-4 Type BF Patient Leakage Current Test - Probe 10-7-4-1 Definition This test measures the current that would flow to ground from any of the probes through a patient who is being scanned and becomes grounded by touching some other grounded surface.
Page 306
GE H RAFT LOGIQ™ S8 EALTHCARE 5394227, R DRAFT (N 17, 2011) IRECTION EVISION OVEMBER ERVICE ANUAL 10-7-5 Type BF Patient Leakage current - Mains to Probe Reference the procedure in the IEC 60601-1. Measure leakage current flow from mains to Probe.
Page 307
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL INDEX Index...
Page 308
GE H LOGIQ™ S8 EALTHCARE 5394227, R IRECTION EVISION ERVICE ANUAL Index...