Software Options; Options - GE LOGIQ S8 Service Manual

Hide thumbs Also See for LOGIQ S8:
Table of Contents

Advertisement

GE H
RAFT
EALTHCARE
D
5394227, R
IRECTION
EVISION
Section 5-4

Software Options

5-4-1

Options

Following options are offered for LOGIQ™ S8.
Table 5-2
Software Options
Advanced 3D
Auto IMT
B-Flow
Coded Contrast Imaging
CW Doppler
DICOM
Elastography
Elasto QA
Flow QA
LOGIQView
Report Writer
Scan Assistant
Stress Echo
TVI (Tissue Velocity Imaging)
5-8
3
DRAFT (N
Software Options
Designed for rendering B Mode and Color Flow Mode images, e.g., vessel trees.
automatically measures the thickness of the Intima Media on the far and near vessel walls.
Near Wall IMT is the distance between the trailing edges of the adventitia and intima; the
Far Wall IMT is the distance between the leading edges of the adventitia and intima.
intended to provide a more intuitive representation of non-quantitative hemodynamics in
vascular structures. All B-Mode measurements are available with B-Flow active: depth,
distance along a straight line, % stenosis, volume, trace, circumference, and enclosed area.
Provides contrast imaging capability
Allows examination of blood flow data all along the Doppler Mode cursor rather than from
any specific depth. Gather samples along the entire Doppler beam for rapid scanning of the
heart. Range gated CW allows information to be gathered at higher velocities.
To enable DICOM connection to network device
Elastography shows the spatial distribution of tissue elasticity properties in a region of
interest by estimating the strain before and after tissue distortion caused by external or
internal forces. The strain estimation is filtered and scaled to provide a smooth presentation
when displayed.
Provides QAnalysis function in Elastography
Provides QAnalysis function in Flow
provides the ability to construct and view a static 2D image which is wider than the field of
view of a given transducer. This feature allows viewing and measurements of anatomy that
is larger than what would fit in a single image. Examples include scanning of vascular
structures and connective tissues in the arms and legs.
Provides output to external printers
provides an automated exam script that moves you through an exam step-by-step. This
allows you to focus on performing the exam rather than on controlling the system and can
help you to increase consistency while reducing keystrokes.
provides an integrated stress echo package, with the ability to perform image acquisition,
review, image optimization, and wall segment scoring and reporting for a complete, efficient
stress echo examination.
calculates and color-codes the velocities in tissue. The tissue velocity information is
acquired by sampling of tissue Doppler velocity values at discrete points
Section 5-4 - Software Options
17, 2011)
OVEMBER
Description
LOGIQ™ S8
S
M
ERVICE
ANUAL