Removal
The procedures below details how to remove the control power supply.
3HAC027707-001 Revision: D
Action
1.
DANGER!
Before any work inside the cabinet, please
observe the safety information in section
DANGER - Make sure that the main power has
been switched off! on page
2. Loosen the attachment screws and pull the
front with the Panel Board Unit in the arrow
direction.
3. Disconnect the connectors X1 - X4 on the
control power supply.
4. Loosen the attachment screw and push the
power supply up to release it from the cap nut.
5. Remove the power supply unit.
4 Repair activities, controller IRC5
4.3.1. Replacement of control power supply
Note/Illustration
26.
xx0600003233
xx0600003229
Continued
A: attachment screws
A: cap nut
B: attachment screw
Continues on next page