ABB IRC5 Product Manual page 249

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

1
2
MAIN SERVO DRIVE UNIT
-A41.1
-X2
Spare
Spare
1 1
+24V
2 2
0V
6 6
DATA_TO_DRIVE
7 7
DATA_TO_DRIVE_N
11
11
ENABLE
12
12
ENABLE_N
3 3
4 4
CLK
8 8
CLK_N
9 9
DATA_TO_RECT
13
13
DATA_TO_RECT_N
14
14
0V
5 5
+5V
10
10
Latest revision:
Prepared by, date:
Approved by, date:
3
-A41.2
1/BK
1/BN
2/BK
2/RD
3/BK
3/OG
4/BK
4/YE
6/BU
5/GN
5/BK
6/BK
7/BK
7/VT
4
5
CONTACTOR UNIT
RECTIFIER
-X32
1 1
2 2
3 3
4 4
-X30
1 1
2 2
6 6
7 7
11
11
12
12
3 3
4 4
8 8
9 9
13
13
14
14
5 5
10
10
DC-BUSBAR
Lab/Office:
IRC5 PANEL MOUNTED CONTROL
RECTIFIER AND BLEEDER
6
7
BLEEDER
-X33
-132
AWG16 BK
1 1
-R1.1
-133
AWG16 BK
2 2
IRB 140, 340 R1.1 = 22 OHM ( NO RESISTOR R1.2 )
IRB 260, 1600, 2400 R1.1 AND R1.2 = 47 OHM
-X31
1 1
2 2
3 3
4 4
Status:
2008-09-01
Approved
Document no.
3HAC026871-005
8
-134
AWG16 BK
1
1
-R1.2
2
2
-135
AWG16 BK
=
Plant:
CAB
+
Location:
DM
+
Sublocation:
Rev. Ind
Page 67
Next
68
03
Total
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents