3HAC027707-001 Revision: D
Action
2.
esd
WARNING!
The unit is sensitive to ESD, before
handling the unit please observe the
safety information in section
WARNING - The unit is sensitive to
ESD! on page 27
3. Fit the DSQC 612 Ethernet board
into the computer unit.
4. Place the additional drive module in
position and secure it with the
included screws and washers.
5. Route and strap the cables as
shown in the illustration.
NOTE!
The attachement plates on the
cables must be connected to the
same ground point as the modules
6. Connect the ethernet cable
(A32.X9) to the DSQC 612 Ethernet
board.
Connector:
A32.X9 to Ethernet board
connector, AXC1
2 Installation and Commissioning, IRC5
2.9.2. Installation of additional Drive Module
Info/Illustration
How to fit the Ethernet board is detailed in
section
Replacement of PCI boards in the
computer unit DSQC639 on page 137
See
Installation, IRC5 Panel Mounted Controller
on page 36
xx0600003393
A: Fit to Control Module ground point
B: Fit to Drive Module ground point
C: Panel Board/Contactor interface board
cable
D: Ethernet cable
Continued
Continues on next page