ABB IRC5 Product Manual page 217

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

1
2
PANEL BOARD
-A21
Latest revision:
Prepared by, date:
Approved by, date:
3
4
/29;7 / -RCH1
/29;6 / -RCH2
/28;4 / -SPEED
/29;5 / -ENABLE2_1
/29;5 / -ENABLE2_2
/29;5 / -ENABLE2_3
/29;5 / -ENABLE2_4
5
-X7
0V
1 1
2 2
24V PANEL
4 4
3 3
5 5
6 6
ENABLE2_1Ret
7 7
8 8
9 9
10
10
-X8
RUN CH1Ret
0V
1 1
2 2
RUN CH2Ret
24V PANEL
4 4
3 3
5 5
ENABLE2_2
6 6
ENABLE2_2Ret
7 7
8 8
9 9
10
10
-X14
RUN CH1Ret
1 1
0V
2 2
RUN CH2Ret
4 4
24V PANEL
3 3
5 5
ENABLE2_3
6 6
ENABLE2_3Ret
7 7
8 8
9 9
10
10
-X17
RUN CH1Ret
1 1
0V
2 2
RUN CH2Ret
4 4
24V PANEL
3 3
5 5
ENABLE2_4
6 6
ENABLE2_4Ret
7 7
8 8
9 9
10
10
Lab/Office:
IRC5 PANEL MOUNTED CONTROL
RUN CHAIN
6
7
CONTROL
MODULE
RUN CH1
-RUN_CH1 / /63;2
RUN CH1Ret
-RUN_CH1Ret / /63;2
RUN CH2Ret
-RUN_CH2Ret / /63;2
RUN CH2
-RUN_CH2 / /63;2
SPEED
-SPEED / /63;2
0V
-0V / /63;2
ENABLE2_1
-ENABLE2_1 / /63;2
-ENABLE2_1Ret / /63;2
AC_ON1
0V
RUN CH1
RUN CH2
BU
SPEED
0V
if not used
Drive
module2
BU
A43.X1
AC_ON1
if not used
0V
RUN CH1
RUN CH2
BU
SPEED
Drive
0V
if not used
module3
A43.X1
BU
AC_ON1
if not used
0V
RUN CH1
RUN CH2
BU
SPEED
Drive
0V
if not used
module4
A43.X1
BU
AC_ON1
if not used
0V
Status:
2008-09-01
Plant:
Location:
Approved
Sublocation:
Document no.
3HAC026871-005
8
Drive
module1
A43.X1
=
CAB
+
CM
+
Rev. Ind
Page 30
Next
31
03
Total
69

Hide quick links: