Description
4
Fine Tune X:
5
Fine Tune Y:
Specifies the amount of adjustment for X/Y axis to the selected row or/and column.
-45.000 to +45.000 mm
-55.000 to +55.000 mm
Setting Range
-80.000 to +80.000 mm
-27.500 to +27.500 mm
6
Rotation Angle:
Specifies the rotation angle of the selected row or/and column. The rotation center is the origin of the each pattern
which is specified in character, logo or barcode condition.
Setting Range
-180.00 to +180.00 degree
7
Laser Power Adj. (Laser Power Adjustment):
Specifies the laser power adjustment amount of the pattern which is specified in the above Fine Adj. Instruction,
Row, and Column.
Setting Range
-50 to +50 %
Reference
• For the marking pattern which more than one fine adjustment is set, the laser power adjustment value is the total
amount of the each settings.
In that case, the available range of the laser power adjustment is +/- 50%.
1st line
:
laser power adjustment +20%
1st row
:
laser power adjustment 10%
[Total amount of the laser power] 20%+10%=30%.
8
Step and Repeat Fine-adjustment
List of fine adjustment instruction for each pattern.
Setting Range
0 to 99 (totally 100 instructions)
Reference
• With selecting the fine-adjust setting in this list and open the image screen, the selected pattern is indicated in green.
• To show the settings of each pattern, select the line of the list and click it again.
9
INPUT:
Sets the instructing content to the selected line from the list of the fine adjustment for the Step & Repeat by
pressing INPUT button. (Not pressing INPUT button does not activate the fine adjustment.)
Reference
• If some parameters are already set in the selected line, they are overwritten with clicking "INPUT". Make sure that the
correct line is selected before clicking "INPUT".
10
DELETE:
Deletes the instruction for fine adjustment set to the list of the fine adjustment for the Step & Repeat.
11
ALL DEL:
Deletes all instruction for fine adjustment set to the list of the fine adjustment for the Step & Repeat.
Reference
• The settings of "Common Condition" in "General Condition" are reflected after the settings in "Step & Repeat"are applied.
(LP-V10)
(LP-430 / LP-420 / LP-410)
(LP-435 / LP-425 / LP-V15)
(LP-431 / LP-421 / LP-411 / LP-W052)
ME-LP400V-OP-6
A
A A A A A A A A A
A
A
A
A
179

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-400 seriesLp-w series

Table of Contents