Panasonic LP-V Series Operation And Maintenance Manual page 196

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

2D Condition Setting Screen
1
2
3
4
8
7
Description
1
Composite Row Height :
Specifies the height of one column of 2D code. Input larger value than "line width" specified by laser setting.
Setting Range
2
Rows Number :
Specifies the number of row of 2D code. The minimum number of row is generated in case of setting 0.
The value that can be input is different according to the combination of 1D and 2D codes. If an invalid combination
is input, it becomes a generation error.
3
Columns Number (CC-C only) :
Specifies the number of column (width in horizontal).
Adjusts the width as close as that of linear bar code by the automatic operation in case of setting 0.
Note that the maximum number of column × rows is 928.
Setting Range
4
Error Correction Level (CC-C only) :
Specifies the error correction level. There are 9 levels (0 to 8) for the error correction level.
When "9" is selected, the recommended value specified in the specification is selected.
Setting Range
5
Quiet / (W) Ratio :
Sets the size of 2D Quiet zone in the ratio to width of a basic module*.
* Basic module: fine element width (basic module width) set on the condition setting screen of 1D.
Setting Range
6
Separator Height/(W) :
Specifies the height of the separation pattern between 1D and 2D symbols in the ratio to width of a basic module.
Setting Range
196
9
0.050 to 9.999 mm
0 to 30
0 to 9
0.0 to 20.0
0.0 to 10.0
5
6
ME-LP400V-OP-6