1-6-3 DIP Switch

• The DIP switch is located in rear of the controller. Refer to "1-6-2 Controller" (P.53).
• The all DIP switch is set to OFF side at factory shipment.
• Switch the DIP switch with the power be shut down.
• A plastic cover is installed on the DIP switch. Install this cover always to avoid the dust penetration to the controller.
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
CAUTION
No. 7 / No. 8
Switch for system reservation. Keep OFF of this switch.
Selects external control method of "Laser Pumping" and "Shutter Control".
ON
Indicates "Laser Pumping", "Shutter Control", "Guide Laser Control", "Laser Check
Radiation", and "Power Check" are externally controlled using serial communication. *1
OFF
Indicates "Laser Pumping" and "Shutter Control" are controlled using I/O terminal.
*1 : "Guide Laser Control", "Laser Check Radiation", and "Power Check" can be controlled
only using serial communication in the remote mode.
Sets buzzer for error occurrence.
ON
This setting does not sound buzzer when occurring error.
OFF
This setting sounds buzzer when occurring error.
Selects valid/invalid for password lock when shifting screen from operation to each setting
one.
ON
Sets invalid for password lock.
OFF
Sets valid for password lock.
Refer to "Password" (P.255) for the detail.
Selects shifting method for the remote mode.
ON
Controls switching to the remote mode from the I/O terminal block.
OFF
In case of shifting mode into remote mode using the remote switch on the front of the
controller. (To set No. 6 to ON, set No. 5 to OFF.)
Selects status when the key switch is turned ON.
ON
Shifts to the remote mode by setting the key switch to ON.
OFF
Does not shift to the remote mode by turning the key switch ON.
(To set No. 5 to ON, set No. 6 to OFF.)
• If the DIP switch No. 5 or No. 6 are used while turned on, construct a system
for re-pumping the laser manually as safety protection measures after the
stop of the laser radiation due to an interlock or other safety functions.
These switches cannot be used. Keep OFF of both No. 7 and No. 8.
ME-LP400V-OP-6