Item
Applicable OS for PC
software
Required time for
system startup
Required time for laser
pumping
Power voltage
100V AC
Power
consumption
*10
200V AC
Grounding method
Cooling method
Ambient temperature *1 1
Ambient temperature for
storage *1 1
Ambient humidity *1 1
Overvoltage category
Pollution degree
Use location
Head
Weight
Controller
Type
Battery
Model
(Embedded
Quantity
in product)
Weight
*1 : Average output power from the laser oscillator at delivery time with the laser power setting 100.
*2 : Value of output 20% or larger, and at 10 min passed after starting-up.
*3 : Work distance has an individual error of approx.+/-2 mm per product.
*4 : The descried values are available ranges for configuration. The marking quality may vary depending on materials of
marking objects and marking conditions.
*5 : Depending on the marking data, the available scan speed might be limited in case the continuous marking more than
1 minute with high scan speed is set.
*6 : For using SQRC, an optional software is needed. SQRC marking function is available only for use in Japan.
*7 : VEC is a graphic file format dedicated for the laser marker. To use HPGL, BMP or JPEG files, convert them to VEC
format with the attached "Logo Data Conversion software". To use AI or EPS files, convert them to VEC format with
the attached software "ExportVEC".
*8 : Check the performance and operation before use. USB media with security features cannot be used.
*9 : The power supply voltage switches automatically.
*10 : The typical value of the inrush current at system startup is 40A. (Duration time is 10 ms or less.)
*11 : This specification is applied to both controller and head. No condensation and freezing shall be allowed. If there is
a gap between the stored temperature and operating temperature, make sure to have the product get used to the
operating ambient temperature gradually prior to use to prevent the dew condensation.
LP-430U
LP-420S9U
LP-410U
LP-430TU
LP-420S9TU
LP-410TU
®
Windows
Windows
®
Vista Business 32bit / Windows
90V to 132V AC or 180V to 264V AC (including ±10% voltage fluctuations) *9
670VA
1000VA or less
or less
700VA
1200VA or less
or less
Head: Forced air-cooling, Controller: Forced air-cooling
Indoor; at an altitude of 1000 m or below
Approx.
Approx. 20 kg
16 kg
Approx.
Approx. 12 kg
11 kg
ME-LP400V-OP-6
Model
LP-431 U
LP-421S9U
LP-431TU
LP-421S9TU
10 Pro 32bit, 64bit / Windows
®
Windows
7 Professional 32bit, 64bit
Approx. 75 sec.
Approx. 15 sec.
Frequency: 50/60 Hz
1000VA or less
1200VA or less
Controller: Direct Earth
0 °C to +40 °C
-10 °C to +60 °C
35 to 85%RH
2
Approx. 20 kg
Approx. 12 kg
Graphite Fluoride Lithium Battery
BR-1 / 2AAC2P
1 piece
Approx. 9.5 g
LP-41 1 U
LP-435U
LP-425S9U
LP-41 1TU
LP-435TU
LP-425S9TU
®
8 Pro 32bit, 64bit /
®
XP Professional 32bit
670VA
1000VA or less
or less
700VA
1200VA or less
or less
Approx.
Approx. 20 kg
16 kg
Approx.
Approx. 12 kg
11 kg