2-1-5 Installation of the Controller

The installation method of the controller is common to LP-400, LP-V and LP-W series.
⿎ Installation Method and Direction
• The controller can be fixed from the bottom or side surfaces with M5 screw at four locations.
• When the side surface is the mounting surface, set the key-switch side down.
• For the installation dimension, refer to "Controller" (P.42) for LP-400series, "Controller" (P.44) for LP-V/LP-W series.
• The inserting length of the screw shall be 4 mm to 6 mm.
• Tightening torque: 2.0 N·m or less.
• The rubber feet can be mounted either on bottom or side face. For the rubber feet installation, use the attached M5
depth 15 mm screws.
⿎ Installation Space
For the appropriate air cooling, provide space around the device as shown in the following figure.
Notice
• Ensure the minimum bent radius of each cable.
• Please install not to bar the flow of air cooling.
• Installing near a heating element could be over ambient temperature and cause malfunction of the product.
• Check the length of the screw and install it. Using improper screws and forcibly tightening them might damage the
product.
M5 Screw
q
50mm
150mm
ME-LP400V-OP-6
w
200mm
50mm
Intake air
q
Exhaust
w
M5 Screw
67