Installation Of Lp-400 Series Head - Panasonic LP-V Series Operation And Maintenance Manual

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

2-1-2 Installation of LP-400 Series Head

WARNING
⿎ Installation Method
• Install the head on a plate with a thickness of 10 mm to 15 mm which is made of aluminum or other material with
radiation performance equivalent to that of aluminum.
• For the installation dimension, refer to the outer dimension in "1-4-1 LP-400 Series" (P.40).
• Fix the head with the following conditions.
Head type
Fixing position
Standard head
Bottom face
Tower head
Rear face
Bottom face
(Laser emission port side)
Standard Head Model
1 1
3
8 7
2 0
0
1 8
0
Notice
• Check the length of the screw and install it. Using improper screws and forcibly tightening them might damage the
product.
• Install the product so that the laser beam path does not cross the eye height.
• The laser beam path shall be enclosed with protective enclosure and make sure
it is not exposed with direct light or reflected light.
Fixing screw
M6 screws at 6
positions
Laser marker
Inserting length of the screw (See above table for the length.)
Washer thickness + stand thick
M6 screw
1 8
0
0
1 3
ME-LP400V-OP-6
Inserting length of the screw
7 mm to 10 mm
7 mm to 10 mm
5 mm to 7 mm
Tower Head Model
Tightening torque
3.0N・m or below
0
1 5
61