Display the extended option output settings once more, and then touch
5.
option output which was saved in step 5 to the sewing machine.
6. Read short sewing data of approximately 10 stitches. Set the memory switch No. 50 to 4 (the work clamp is not are
automatically raised when sewing is completed). Carry out sewing operation.
Confirm that the left work clamp is in the raised position, that it stays in that position for one second, and then
lowers whenever the needle returns to the sewing start point. If the left work clamp operates in this manner, it is
operating in accordance with the program.
 Modifying programmed data
Modify existing program data according to the procedure described in "Turning the output interlocking on and off
corresponding to sewing machine operations".
1. Display the extended option output settings.
2. Touch
.
Load the programs which have already been written.
3. Display the output setting screen. Set Timer 1 to 0.5 sec. (500 ms) and Timer 2 to 0.5 sec. (500 ms).
On the setting screen, make the following settings.
The existing "1000" setting for timer 2 will be refreshed and overwritten with "500".
4. Carry out steps 4 to 6 in "Turning the output interlocking on and off corresponding to sewing machine operations"
to overwrite the extended option output.
5. Carry out sewing operation. Confirm that the time that elapses after the needle returns to the sewing start point until
the left work clamp rises is longer (since the setting for Timer 1 has been changed from 0 to 0.5 sec.), and that the
length of time the work clamp takes to rise is less (since the setting for Timer 2 has been changed from 1 to 0.5
sec.).
CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
BAS H series, Programmer
to apply the extended
93