CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
How to create programs
Selecting hardware on the output side
Use NPN open collector outputs.
Circuit board
+24V
It is assumed that an optionally available air valve is used.
In addition to a 24 V air valve, use a 24 VDC relay.
Circuit board
+24V
Fuses are not incorporated into the output circuit. To prevent the circuit from being damaged if the output
short-circuits, it is recommended that you mount an external fuse for each circuit.
Selecting hardware on the input side
・
Use non-isolated IC inputs
Circuit board
+5
4.7KΩ
・
In addition to using a contact switch or a 24 V sensor, use relays to isolate inputs.
Circuit board
+5
4.7KΩ
・
Use relays for an electronic circuit with a min. application load of 5 V and 1 mA or less.
104
COM terminal
Output terminal
External 24V relay
COM terminal
Output terminal
+24V
Input terminal
0
+24V
Input terminal
0
BAS H series, Programmer
I=70 mA
Power
supply
Example connection to a proximity
sensor
Vcc
Sensor output
NPN open collector
Sensor output
0V
External relay
External