 Example 3
Signals for external equipment
When connecting to the external sequence unit, this sequence programs operations to issue timing signals.
Option output 4
Option output 5
Option output 6
Timing chart
Movement of sewing start
point
Movement of sewing start
point when sewing ends.
Program setting values
Output
Operation
No.
setting
Condition
No.
ON
4
OFF
17
5
ON
ON
16
6
OFF
77
READY: Ready-for-sewing signal
END: Sewing end signal
THBK: Thread breakage detection signal
0.1 sec
Output condition
Timer 1
[ms]
Content
Movement of
2
sewing start point
Sewing machine
1
returns to home
position
Change of P. No.
Movement of
2
sewing start point
Thread breakage
detection
8
Start of step back
Output 4 OFF
BAS H series, Programmer
CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
Returning to home position of sewing
machine or change of P. No.
Start of step back or returning to home position
of sewing machine or charge of P. No.
Thread breaking
detection
Enabling conditions
Timer 2
[ms]
Condition
No.
0
0
0
0
0
100
6
0
0
0
0
Disabling conditions
Condition
Content
No.
End of sewing
1
returns to home
Content
Sewing
machine
position
91