Temporary pause during sequence operation
Program Example 1 from the instruction manual. Confirm the option output during temporary pause.
1. Use
to delete the registered extended option output.
2. Referring to Example 1 (Sequence 1 for the stacker) in the programmer instruction manual (refer to page 89),
program outputs of No. 4, 5, and 6 and enabling conditions for No. 4.
3. When the program is working as intended, press the temporary pause switch during the sequence operation to cancel
it.
Operating temporary pause during sequence operation temporarily pauses the sequence. To complete the sequence,
carry out a restore operation.
4. Add condition No. 15 (when the sewing machine enters the temporary pause state), as conditions for output No. 4, 5,
and 6 OFF.
If you press the temporary pause switch, the output is immediately turned off.
CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
BAS H series, Programmer
103