CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
 Controlling commencement of sewing by providing an input check to the
automatic start function
Add option input No. 1 to the enabling conditions in the previous section.
1. Touch
and load the programs which have already been written.
2. Display the enabling condition setting screen. Referring to the table of external input condition numbers (refer to
page 86), set enabling condition No. 1 to "enabling
"disabling
when condition No. 41 (input 1 OFF) is established".
3. Touch
to overwrite the extended option output.
4. Display the extended option output once more, and then touch
was overwritten in step 3 to the sewing machine.
5. As an additional step 7 in "Automating the commencement of sewing", confirm also that sewing commences only
when option input No. 1 is on.
By carrying out sequence control of the raising and lowering of the work clamp using the option output as shown in
the example above, you can configure the sewing machine so that material is automatically loaded before sewing.