 Adding input check to carry out settings of 3-input AND conditions
This example adds "when option inputs No. 1 and 2 are on" to the enabling conditions in the previous example of
"Controlling commencement of sewing by providing an input check to the automatic start function". "After the work
clamp is lowered (condition No. 31)" has been set as the output condition. Accordingly, a total of 3-input AND
conditions are set.
Up to 2-input AND conditions can be set for each option output. 3-input AND conditions are configured so that one
output is set to be virtual output.
In this case, set option output No. 2 as virtual output.
1. Touch
and load the programs which have already been written.
2. Display the extended option output settings.
Referring to the "Extended option output" table of condition numbers (refer to page 86), set the enabling condition
for No. 1 to "Enable
condition No. 73 (output 2 off) is established".
3. Referring to the "External input of the extended option" table of condition numbers (refer to page 86), set the
enabling condition for No. 2 to "Enable setting when condition No. 40 (input 1 on) is established". Enter into the
setting screen as follows.
setting when condition No. 72 (output 2 on) is established". Set "Disable
BAS H series, Programmer
CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
when
101