Measuring a tool
6.5.1 Vertical softkey bar (VSK)
By pressing the VSK 3 "X" the screen area for the
function "Probe calibration" in the X-axis will be se-
lected.
By pressing the VSK 4 "Z" the screen area for the
function "Probe calibration" in the Z-axis will be se-
lected.
By pressing the VSK 8 "Back" you switch back to
the "Measure tool" screen.
6.5.2 Parameters for "Probe calibration"
Measuring direc-
Parameter
tion
6.5.3 Method for "Probe calibration"
1.
Change the calibrating tool.
2
Select the "JOG" mode in the "Machine" operating
area.
3
Press HSK 4 "Meas. Tool" and the VSK 6 "Calibrate
probe".
4.
Press the VSK 3 "X" or the VSK 4 "Z", depending on
which point of the tool probe is meant to determined
first.
5.
Select the direction (+ or -), in which you would like
to approach the tool probe.
6.
Manually position the calibrating tool nearby tool
probe such that any collisions can be avoided when
the first point of the tool probe is being approached.
7.
Press the "CYCLE START" button on the machine
control panel.
The calibration process is started, i.e. the calibrating tool is automatically
traversed with measurement feedrate to the probe and back again. The
position of the tool probe is determined and saved in an internal data area.
8.
Repeat the process for the other three points of the
tool probe.