4 Installation and commissioning

4.2.5 Fastening of a unit to the floor plate

4.2.5 Fastening of a unit to the floor plate
Equipment
The required equipment is the standard toolkit, and in particular:
1
2
3
Procedure
1
2
3
Continues on next page
68
Hex keys (Allen keys) 3 and 6 (socket wrenches recommended)
Torque wrench used with socket head cap 6 mm. See
on page
133.
Two dowel pins Ø8 and eight M8 socket head screws for 190-590 stroke unit (twelve
M8 socket head screws for 670 mm stroke unit).
Action
As it is necessary to jog the first horizontal axis
carriage to tighten all the screws, you must pre-
pare the equipment (controller, cables, SMB box)
necessary to control the unit. See
page
16.
Remove the cover plate (B) of the first horizontal
axis by loosening its six M5x10 Class 8.8 fixing
screws (A).
Remove the cover plate by sliding it from one end
of FlexPLP IRPLP 220.