ABB FlexPLP IRPLP 220 Product Manual page 60

Table of Contents

Advertisement

4 Installation and commissioning
4.2.2 Mounting surface (fastening of the FlexPLP IRPLP 220 to the floor plate)
Continued
Floor Plate
The FlexPLP IRPLP 220 must be secured on a floor plate or a tooling frame. ABB
provide the option of standard floor plate. With the standard floor plate, it is
convenient for replacement of a whole FlexPLP IRPLP 220 unit. Contact ABB if a
floor plate is needed.
xx1800002125
The table below gives the detailed numbers of holes and dimensions depending
on the strokes. For more information about the extra stroke of Rack and Pinion
type, contact ABB.
Stroke
(mm)
190 mm
270 mm
350 mm
430 mm
510 mm
590 mm
670 mm
Continues on next page
60
Length
Length
Length
L0 (mm)
L (mm)
L1 (mm)
470 mm
240 mm
200 mm
550 mm
320 mm
240 mm
630 mm
320 mm
280 mm
710 mm
400 mm
200 mm
790 mm
480 mm
240 mm
870 mm
560 mm
280 mm
950 mm
640 mm
280 mm
© Copyright 2016 - 2018 ABB. All rights reserved.
Length
No. of Ø20
N x M
holes
L2 (mm)
(No. x mm)
0 mm
6
1x80 mm
0 mm
6
1x80 mm
0 mm
6
1x160 mm
240 mm
8
1x160 mm
240 mm
8
1x160 mm
240 mm
8
1x160 mm
320 mm
8
2x160 mm
Product manual - FlexPLP IRPLP 220
3HAW050041018-001 Revision: C