Product manual - FlexPLP IRPLP 220
3HAW050041018-001 Revision: C
Action
Lift FlexPLP IRPLP 220 and position it on the
mounting surface.
Connect the power and resolver cables to the unit.
If needed, use the controller's FlexPendant to
move the first horizontal axis carriage and clear
the access to the countersunk holes and pin holes
of the base body.
Secure the first horizontal axis of FlexPLP IRPLP
220 by installing the following fastening parts on
the basement body: the two dowel pins Ø8 mm(A)
and eight M8 screws with lock washer (B).
Reinstall the first horizontal axis cover.
© Copyright 2016 - 2018 ABB. All rights reserved.
4 Installation and commissioning
4.2.5 Fastening of a unit to the floor plate
Info/Illustration
xx1800002138
xx1800002139
Continued